Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: APOLLO INVESTMENT HOLDING CO., LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of APOLLO INVESTMENT HOLDING CO., LLC in 167 W. KINDT STREET P.O. BOX 106, JUNEAU, WI 53039 (NAICS 332999). OSHA activity number 343624110.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Apollo Investment Holding CO., LLC for free Get an email when a new federal OSHA severe-injury report for Apollo Investment Holding CO., LLC is published. One employer, no account, unsubscribe in one click.
Site address
167 W. KINDT STREET P.O. BOX 106
City
JUNEAU
State
WI
ZIP
53039
Mailing
P.O. BOX 106 THE EMPLOYER AGREES TO WORK WITH A QUALIFIED THIRD PARTY TO CONDUCT A COMPREHENSIVE REVIEW OF THE SA, JUNEAU, WI 53039
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
12
Ownership type
A

3 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 29, 2019
Penalty
Initial $6,630 · Current $4,972 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s).     Riveting Machines - On or about November 28, 2018, the National Rivet (ser. no - 2120) did not have guarding at the point of operation to protect employees from nip point and crushing hazards.
Recent events (2)
  • · I (S) $4972
  • · Z (S) $6630

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 29, 2019
Abate by
Feb 27, 2019
Penalty
Initial $3,978 · Current $2,984 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.    (a) Riveting Machines - On or about November 28, 2018, re-locatable power taps were used in series and or with extension cords at the riveting machines, exposing employees to fire hazards.
Recent events (2)
  • · I (S) $2984
  • · Z (S) $3978

1910.22 B

Other-than-serious 1 instance 2 exposed
Issued
Jan 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface.  a) Storage Upstairs (Office) - On or about November 28, 2018, the maximum intended load for the storage above the main offices was not identified.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343624110.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.