DAYTON, OH —
OSHA Inspection: COMPOSITE TECHNOLOGIES CO. LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMPOSITE TECHNOLOGIES CO. LLC in 401 NORTH KEOWEE STREET, DAYTON, OH 45404 (NAICS 326199). OSHA activity number 343626727.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMPOSITE TECHNOLOGIES CO. LLC
- Site address
- 401 NORTH KEOWEE STREET
- City
- DAYTON
- State
- OH
- ZIP
- 45404
- Mailing
- 401 NORTH KEOWEE STREET, DAYTON, OH 45404
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 40
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 A01
- Issued
- Feb 7, 2019
- Abate by
- Mar 6, 2019
- Penalty
- Initial $10,210 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): (1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. a) On or about 11/29/2018 an employer did not properly ensure that the work place was kept clean in that plastic dust, card board, wood and trash was allowed to accumulate up on the elevated walking working surface of Blender #1 exposing employees to a tripping hazard.
Recent events (3)
- — F (S) $0
- — C (S) $10210
- — Z (S) $10210
1910.147 C01
- Issued
- Feb 7, 2019
- Abate by
- Mar 6, 2019
- Penalty
- Initial $10,210 · Current $7,147 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) On or about 11/29/2018 the employer did not develop an energy control program that consist of energy control procedures, employees training and periodic inspection with respect to the use of lockout in preventing the release of electrical and hydraulic energy during servicing and maintenance of the 9 Power Presses.
Recent events (3)
- — F (O) $7147
- — C (S) $10210
- — Z (S) $10210
1910.212 A01
- Issued
- Feb 7, 2019
- Penalty
- Initial $10,210 · Current $5,105 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a) On or about 11/29/2018 employees were operating the #6 power press with light curtains that were not properly set to protect the operators from the point of operation. b) On or about 11/29/2018 two employees were operating the Cell #3 power press with (2) two hand controls to operate the press. The second set of two hand controls had electrical tape wrapped around the buttons to allow one operator to engage the power press. The computer for the press was set for two operators.
Recent events (3)
- — F (O) $5104.96
- — C (S) $10210
- — Z (S) $10210
1910.303 G02 I
- Issued
- Feb 7, 2019
- Abate by
- Mar 6, 2019
- Penalty
- Initial $10,210 · Current $7,147 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a) On or about 11/29/2018 employees are exposed to live electrical wires of 50 volts or greater, the glass panel to the control box was missing and wires were hanging out of the control box.
Recent events (3)
- — F (S) $7147
- — C (S) $10210
- — Z (S) $10210
More inspections at Composite Technologies CO. LLC
View Composite Technologies CO. LLC's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343626727.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.