Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KEY WEST EXPRESS PLUS, INC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of KEY WEST EXPRESS PLUS, INC in 1230 NW 36TH ST., MIAMI, FL 33142 (NAICS 487110). OSHA activity number 343628731.

Watch KEY West Express Plus, INC — free Get an email when a new federal OSHA severe-injury report for KEY West Express Plus, INC is published. One employer, no account, unsubscribe in one click.
Site address
1230 NW 36TH ST.
City
MIAMI
State
FL
ZIP
33142
Mailing
14020 ALAMANDA AVE, MIAMI LAKES, FL 33014
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
487110
Employees
2
Ownership type
A

10 citations on file for this inspection.

1910.101 B

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3410.00 · Current $2046.00 Reduced
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6:      On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to struck-by hazards while having a nitrogen cylinder not secured while in storage.
Recent events (2)
  • — I (S) $2046
  • — Z (S) $3410

1910.169 B03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2842.00 · Current $1705.00 Reduced
29 CFR 1910.169(b)(3)(i): Every air receiver was not equipped with an indicating pressure gauge (so located as to be readily visible):     On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to struck-by hazards due to air receivers not equipped with an operational pressure gauge.
Recent events (2)
  • — I (S) $1705.2
  • — Z (S) $2842

1910.244 A02 III

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $13260.00 · Current $9282.00 Reduced
29 CFR 1910.244(a)(2)(iii): Loads were not cribbed, blocked or otherwise secured immediately after being raised with a jack:    On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to caught-between hazards while working under loads that were not cribbed, blocked or secured.
Recent events (2)
  • — I (S) $9282
  • — Z (S) $13260

1910.253 B02 IV

Serious Gravity 5 2 instances 1 exposed
Issued
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:     On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to struck-by hazards while cylinders of oxygen and acetylene were stored without a valve cap.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.253 B04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2273.00 · Current $1364.00 Reduced
1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire:    On or about 11/30/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to fire hazards while cylinders of oxygen and acetylene were stored together.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.303 C03 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2273.00 · Current $1364.00 Reduced
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices were not first spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose:    On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, an air compressor had a splice on its cord covered with electrical plastic tape, exposing an employee to an electrical shock hazard.
Recent events (2)
  • — I (S) $1363.8
  • — Z (S) $2273

1910.304 G05

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to electrical hazards while an air compressor lacked a grounding conductor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv).  On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to electrical hazards while an air compressor had temporary wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met  On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, the employer did not implement and develop a written hazard communication program for employees exposed to chemical hazards associated with chemicals including but not limited to, nitrogen, acetylene, oxygen, oils and solvents at the workplace.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use  On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, the employer did not have the safety data sheets for employees exposed to chemical hazards while working with chemicals including but not limited to, nitrogen, acetylene, oxygen, oils and solvents at the workplace.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343628731.