MIAMI, FL ·
OSHA Inspection: KEY WEST EXPRESS PLUS, INC
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of KEY WEST EXPRESS PLUS, INC in 1230 NW 36TH ST., MIAMI, FL 33142 (NAICS 487110). OSHA activity number 343628731.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEY WEST EXPRESS PLUS, INC
- Site address
- 1230 NW 36TH ST.
- City
- MIAMI
- State
- FL
- ZIP
- 33142
- Mailing
- 14020 ALAMANDA AVE, MIAMI LAKES, FL 33014
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 487110
- Employees
- 2
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
1910.101 B
- Issued
- Mar 20, 2019
- Penalty
- Initial $3,410 · Current $2,046 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to struck-by hazards while having a nitrogen cylinder not secured while in storage.
Recent events (2)
- · I (S) $2046
- · Z (S) $3410
1910.169 B03 I
- Issued
- Mar 20, 2019
- Penalty
- Initial $2,842 · Current $1,705 Reduced
General-duty citation text
29 CFR 1910.169(b)(3)(i): Every air receiver was not equipped with an indicating pressure gauge (so located as to be readily visible): On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to struck-by hazards due to air receivers not equipped with an operational pressure gauge.
Recent events (2)
- · I (S) $1705.2
- · Z (S) $2842
1910.244 A02 III
- Issued
- Mar 20, 2019
- Penalty
- Initial $13,260 · Current $9,282 Reduced
General-duty citation text
29 CFR 1910.244(a)(2)(iii): Loads were not cribbed, blocked or otherwise secured immediately after being raised with a jack: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to caught-between hazards while working under loads that were not cribbed, blocked or secured.
Recent events (2)
- · I (S) $9282
- · Z (S) $13260
1910.253 B02 IV
- Issued
- Mar 20, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to struck-by hazards while cylinders of oxygen and acetylene were stored without a valve cap.
Recent events (2)
- · I (S) $1363.8
- · Z (S) $2273
1910.253 B04 I
- Issued
- Mar 20, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: On or about 11/30/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to fire hazards while cylinders of oxygen and acetylene were stored together.
Recent events (2)
- · I (S) $1363.8
- · Z (S) $2273
1910.303 C03 I
- Issued
- Mar 20, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices were not first spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, an air compressor had a splice on its cord covered with electrical plastic tape, exposing an employee to an electrical shock hazard.
Recent events (2)
- · I (S) $1363.8
- · Z (S) $2273
1910.304 G05
- Issued
- Mar 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to electrical hazards while an air compressor lacked a grounding conductor.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.305 G01 IV
- Issued
- Mar 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv). On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, employees were exposed to electrical hazards while an air compressor had temporary wiring.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 E01
- Issued
- Mar 20, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, the employer did not implement and develop a written hazard communication program for employees exposed to chemical hazards associated with chemicals including but not limited to, nitrogen, acetylene, oxygen, oils and solvents at the workplace.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.1200 G01
- Issued
- Mar 20, 2019
- Abate by
- May 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use On or about 11/29/2018, jobsite located at 1230 NW 36th St. Miami, FL 33142, the employer did not have the safety data sheets for employees exposed to chemical hazards while working with chemicals including but not limited to, nitrogen, acetylene, oxygen, oils and solvents at the workplace.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 487110)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343628731.