Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NORDSON XALOY INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of NORDSON XALOY INC. in 375 VICTORIA ROAD, AUSTINTOWN, OH 44515 (NAICS 333999). OSHA activity number 343631677.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nordson Xaloy INC. — free Get an email when a new federal OSHA severe-injury report for Nordson Xaloy INC. is published. One employer, no account, unsubscribe in one click.
Establishment
NORDSON XALOY INC.
Site address
375 VICTORIA ROAD
City
AUSTINTOWN
State
OH
ZIP
44515
Mailing
375 VICTORIA ROAD, AUSTINTOWN, OH 44515
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
260
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 20, 2018
Abate by
Jan 17, 2019
Penalty
Initial $9,239 · Current $6,467 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about November 30, 2018, the employer failed to ensure that the Kingston Heavy Duty 30 Decap lathe (W0208), which was being used in the Decap department, was effectively guarded to protect employees from the hazard of point of operation and flying chips during the operation of the lathe.  The lathe did not have a chuck guard in place.
Recent events (2)
  • — I (S) $6467.3
  • — Z (S) $9239

1910.242 B

Serious Gravity 5 1 instance 30 exposed
Issued
Dec 20, 2018
Abate by
Jan 17, 2019
Penalty
Initial $7,391 · Current $5,174 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  On or about November 30, 2018, the employer failed to ensure the compressed air hoses used at various lathes throughout the building, to include but not limited to the Kingston Heavy Duty 30 lathe (W0159) that is located in the Group 2 area, was designed such that it was able to control the flow of air to a maximum 30 psi.  The hose was tested onsite and registered a reading in excess of 70 psi. The air hoses are used to clean off the lathe, miscellaneous parts, and other debris.
Recent events (2)
  • — I (S) $5173.7
  • — Z (S) $7391

View Nordson Xaloy INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343631677.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.