OSHA Inspection: G. M. NORTHRUP CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G. M. NORTHRUP CORPORATION in 1929 CENTRAL AVE, ALBANY, NY 12205 (NAICS 236220). OSHA activity number 343632972.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G. M. Northrup Corporation — free Get an email when a new federal OSHA severe-injury report for G. M. Northrup Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1929 CENTRAL AVE
City
ALBANY
State
NY
ZIP
12205
Mailing
15950 FRANKLIN TRL SE, PRIOR LAKE, MN 55372
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
12
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 18, 2019
Penalty
Initial $3,141 · Current $2,042 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    (a)1929 Central Ave Colonie, NY - On or about 11/29/18 J Dunn Group employees were inside an excavation with an approximate depth of 6.5 feet.  The employees were exposed to possible engulfment hazard with no means of egress as they dug out the main water line.
Recent events (2)
  • — I (S) $2041.65
  • — Z (S) $3141

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 18, 2019
Penalty
Initial $3,141 · Current $2,042 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).    (a)1929 Central Ave: On or about 11/29/18,  J Dunn Group employees were in a trench measuring approximately 6.5 feet deep without protection from cave in.  The employees were installing a water pipe for a fire hydrant.
Recent events (2)
  • — I (S) $2041.65
  • — Z (S) $3141

View G. M. Northrup Corporation's full OSHA safety record →