Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: COPPER TOP BREWERY, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of COPPER TOP BREWERY, LLC in 151 COMMERCE RD, BOYNTON BEACH, FL 33426 (NAICS 312120). OSHA activity number 343637856.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Copper TOP Brewery, LLC for free Get an email when a new federal OSHA severe-injury report for Copper TOP Brewery, LLC is published. One employer, no account, unsubscribe in one click.
Site address
151 COMMERCE RD
City
BOYNTON BEACH
State
FL
ZIP
33426
Mailing
151 COMMERCE RD, BOYNTON BEACH, FL 33426
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312120
Employees
16
Ownership type
Private (A)

8 citations on file for this inspection.

1910.36 D01

Serious Gravity 10 1 instance 16 exposed
Issued
May 9, 2019
Penalty
Initial $5,304 · Current $3,182 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  On or about November 28, 2018, at 151 Commerce Road, Boynton Beach, FL 33426, the employer allowed its employees to work at a jobsite where designated Exit doors had locks, where employees can possibly be trapped and exposed to smoke inhalation, burns and possible death.
Recent events (2)
  • · I (S) $3182.4
  • · Z (S) $5304

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2019
Penalty
Initial $3,789 · Current $2,273 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    On or about November 28, 2018, at 151 Commerce Road, Boynton Beach, FL 33426, the employer did not provide suitable facilities for quick drenching or flushing of the eyes and body were readily available in the work area for immediate use to employees who were required to work with hazardous chemicals, including, but not limited to, HDX Germicidal Bleach (a corrosive, with a pH of 12.5), L-lactic Acid (a corrosive, with a pH of less than 1.2), and Phosphoric Acid 75% (a corrosive, with a pH of less than 1).
Recent events (2)
  • · I (S) $2273.4
  • · Z (S) $3789

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2019
Penalty
Initial $3,789 · Current $2,273 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  On or about November 28, 2018, at 151 Commerce Road, Boynton Beach, FL 33426, the employer did not develop and implement a written hazard communication program for employees who were required to work with hazardous chemicals, including, but not limited to, HDX Germicidal Bleach (a corrosive, with a pH of 12.5), L-lactic Acid (corrosive, pH less than 1.2), and Phosphoric Acid 75% (a corrosive, with a pH of less than 1).
Recent events (2)
  • · I (S) $2273.4
  • · Z (S) $3789

1910.1200 H01

Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or about November 28, 2018, at 151 Commerce Road, Boynton Beach, FL 33426, the employer did not provide effective information and training for employees who were required to work with hazardous chemicals, including, but not limited to, HDX Germicidal Bleach (a corrosive, with a pH of 12.5), L-lactic Acid (corrosive, pH less than 1.2), and Phosphoric Acid 75% (a corrosive, with a pH of less than 1).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
May 9, 2019
Abate by
Jun 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  On or about November 28, 2018, at 151 Commerce Road, Boynton Beach, FL 33426, the employer did not have a written respiratory protection program for employees required to wear 3M Reusable Half Face Mask Respirators in the workplace.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 E01

Other-than-serious 1 instance 2 exposed
Issued
May 9, 2019
Abate by
Jun 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.  On or about November 28, 2018, at 151 Commerce Road, Boynton Beach, FL 33426, the employer did not provide medical evaluations prior to requiring employees to wear 3M Reusable Half Face Mask Respirators in the workplace.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 F01

Other-than-serious 1 instance 2 exposed
Issued
May 9, 2019
Abate by
Jun 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer shall ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph.  On or about November 28, 2018, at 151 Commerce Road, Boynton Beach, FL 33426, the employer did not ensure fit testing was conducted  for employees required to wear 3M Reusable Half Face Mask Respirators in the workplace.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 G01 II

Other-than-serious 1 instance 16 exposed
Issued
May 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  On or about November 28, 2018, at 151 Commerce Road, Boynton Beach, FL 33426, the space in front of an electrical panels was not maintained and was obstructed by storage, impeding quick access to the electrical panels.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343637856.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.