VILLA PARK, IL —
OSHA Inspection: KEPNER PRODUCTS COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KEPNER PRODUCTS COMPANY in 995 N. ELLSWORTH AVE., VILLA PARK, IL 60181 (NAICS 332911). OSHA activity number 343642559.
Where did this inspection happen?
- Establishment
- KEPNER PRODUCTS COMPANY
- Site address
- 995 N. ELLSWORTH AVE.
- City
- VILLA PARK
- State
- IL
- ZIP
- 60181
- Mailing
- 995 N. ELLSWORTH AVE., VILLA PARK, IL 60181
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332911
- Employees
- 58
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $3200.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about December 11, 2018, an employee was operating an Okuma LB 15 # 2. The machine door was able to be opened approximately 5 inches before the interlocks engaged. The employee was exposed to rotating parts, flying particles and splashing of chemicals. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $3200
- — Z (S) $5304
1910.332 B01
- Issued
- Abate by
- Penalty
- Initial $9282.00 · Current $5600.00 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments. On or about November 1, 2018, and after, employee(s) performed voltage testing on 240 volts on energized components inside electrical supply boxes. Employees were not trained in and familiar with safety-related work practices such as the use of special precautionary techniques, personal protective equipment (PPE) and insulating and shielding materials. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $5600
- — Z (S) $9282
1910.333 A
- Issued
- Abate by
- Penalty
- Initial $9282.00 · Current $5600.00 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: On or about November 1, 2018 and after, employee(s) were required to use a multi meter to test 240 volts on live energized components inside electrical supply boxes. The employer failed to ensure the use of safety related work practices before employees began to work on or near live parts to protect employees from arc flash, electric shock and/or electrocution. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $5600
- — Z (S) $9282
1910.335 A01 I
- Issued
- Abate by
- Penalty
- Initial $9282.00 · Current $5600.00 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed. On or about November 1, 2018 and after, employee(s) were required to perform voltage testing on 240 volts on energized components inside electrical supply boxes. The employer failed to provide electrical protective equipment appropriate for the specific parts of the body to be protected when they performed such tasks in areas where they had the potential to come into contact with energized equipment or encounter arc flash hazards. Employees did not wear appropriate electrical protective equipment including, but not limited to, the following to protect against electrical shock injuries: a) Rubber insulating gloves with leather protectors b) Arc-Rated clothing such as arc-rated long-sleeve shirt and pants, or arc-rated coverall c) Hearing protection (canal inserts) d) Arc-Rated flash suit, hood or balaclava Abatement documentation is required of this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
- — I (S) $5600
- — Z (S) $9282
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program. On or about December 4, 2018, the employer did not implement and maintain a written hazard communication program at the workplace. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1904.41 A02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1904.41(a)(2): Annual electronic submission of OSHA Form 300A Summary of Work-Related Injuries and Illnesses by establishments with 20 or more employees but fewer than 250 employees in designated industries. If your establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and your establishment is classified in an industry listed in appendix A to subpart E of this part, then you must electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form. On or about July 1, 2018, the employer failed during calendar year 2018, to electronically submit the company's 2017 data from their OSHA Form 300A or equivalent by July 01, 2018. The establishment is classified under NAICS 332911 and employed more than 20 employees during calendar year 2017. No documentation or certification required.
Recent events (1)
- — Z (O) $0
More inspections at KEPNER PRODUCTS COMPANY
VILLA PARK, IL—1997-01-09 00:00:00
KEPNER PRODUCTS COMPANY
View KEPNER PRODUCTS COMPANY's full OSHA safety record →
More inspections in this industry (NAICS 332911)
PRAIRIE DU SAC, WI—2026-06-25
MILWAUKEE VALVE COMPANY, LLC
SELMA, CA—2026-06-16
FRESNO VALVES & CASTINGS, INC.
PITTSBURGH, PA—2026-06-12
RED VALVE COMPANY
FRANKFORT, MI—2026-05-18
ROSS DECCO COMPANY
CONOVER, NC—2026-04-23
161108 - ENGINEERED CONTROLS INTERNATIONAL, INC.
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343642559.