SEATTLE, WA ·
OSHA Inspection: NATIONAL ARCHIVES AND RECORDS ADMINISTRATION; PACIFIC ALASKA REGION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL ARCHIVES AND RECORDS ADMINISTRATION; PACIFIC ALASKA REGION in 6125 SAND POINT WAY NE, SEATTLE, WA 98115 (NAICS 493190). OSHA activity number 343645560.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 6125 SAND POINT WAY NE
- City
- SEATTLE
- State
- WA
- ZIP
- 98115
- Mailing
- 6125 SAND POINT WAY NE, SEATTLE, WA 98115
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493190
- Employees
- 20
- Ownership type
- Federal government (D)
Citations
10 citations on file for this inspection.
1910.178 L04 III
- Issued
- Jan 29, 2019
- Abate by
- Mar 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Trained forklift drivers did not have an evaluation at least once every three years with written documentation of the date of the evaluation and name of person performing the training or evaluation.
Recent events (1)
- · Z (S) $0
1910.178 L06
- Issued
- Jan 29, 2019
- Abate by
- Feb 11, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6):The employer did certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation: a) Trained forklift trained drivers did not have written documentation stating the name of the operator, training date, evaluation date and name of trainer.
Recent events (1)
- · Z (S) $0
1910.178 Q07
- Issued
- Jan 29, 2019
- Abate by
- Feb 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined at least daily before being placed in service. a) Forklifts were not examined daily or before each use, if forklift use occurs less often.
Recent events (1)
- · Z (S) $0
1910.303 B02
- Issued
- Jan 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Bat Cave/ Imaging Room; A full size GE refrigerator was plugged into a surge protector power strip (relocatable power tap). The UL listing states that relocatable power taps are designed for low amperage computer and audiovisual types of equipment, and not appliances. This exposes employees to possible electrical fire hazards.
Recent events (1)
- · Z (S) $0
1910.305 G01 I
- Issued
- Jan 29, 2019
- Abate by
- Feb 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(i): Flexible cords and cables were not approved for conditions of use and location: a) Kitchen; A Rival can opener and Rival toaster were plugged into a brown extension cord.
Recent events (1)
- · Z (S) $0
1910.37 A03
- Issued
- Jan 29, 2019
- Abate by
- Feb 11, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not kept free and unobstructed. Materials or equipment were placed, either permanently or temporarily, within the exit route: a) North Dock; A shelving unit with stored parts/equipment was located adjacent to the exit discharge door for the area.
Recent events (1)
- · Z (O) $0
1910.37 B05
- Issued
- Jan 29, 2019
- Abate by
- Feb 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) Red Room; Two double sets of doors were located in the room and the doors which lead to the phone closet were not marked not an exit or phone closet.
Recent events (1)
- · Z (O) $0
1910.134 C02 I
- Issued
- Jan 29, 2019
- Abate by
- Feb 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: a) Employees who voluntarily use 3M 8210 N95 dust masks were not provided with the information in Appendix D of the respirator standard.
Recent events (1)
- · Z (O) $0
1910.157 C01
- Issued
- Jan 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Upstairs conference room; An Amerex fire extinguisher was blocked by a small file cabinet and phone.
Recent events (1)
- · Z (O) $0
1960.25 C
- Issued
- Jan 29, 2019
- Abate by
- Feb 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1960.25(c): 29 CFR 1960.25(c): The Agency did not inspect annually, all areas in each workplace, including office operations: a) The work area was not inspected (by internal NARA employees) for possible health and safety hazards annually. Note: The annual inspection should be documented, and a copy of the inspection report should be available at the location.
Recent events (1)
- · Z (O) $0
More inspections at National Archives and Records Administration; Pacific Alaska Region
View National Archives and Records Administration; Pacific Alaska Region's full OSHA safety record →
More inspections in this industry (NAICS 493190)
More inspections in WA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343645560.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.