ERIE, PA ·
OSHA Inspection: FMC TECHNOLOGIES MEASUREMENT SOLUTIONS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FMC TECHNOLOGIES MEASUREMENT SOLUTIONS, INC. in 1602 WAGNER AVENUE, ERIE, PA 16510 (NAICS 333132). OSHA activity number 343646667.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FMC TECHNOLOGIES MEASUREMENT SOLUTIONS, INC.
- Site address
- 1602 WAGNER AVENUE
- City
- ERIE
- State
- PA
- ZIP
- 16510
- Mailing
- 1602 WAGNER AVENUE, ERIE, PA 16510
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333132
- Employees
- 185
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Feb 8, 2019
- Abate by
- Mar 7, 2019
- Penalty
- Initial $5,796 · Current $3,535 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: A.) FMC Technologies Measurement Solutions, Inc. - On or about 12/6/18, and at times prior thereto, employees were performing servicing and maintenance on machinery and equipment that included, but were not limited to, Oven 8204 and Vertical Mill 2119. The company did not perform periodic inspections of the lockout/tagout procedures within the last 12 months with all authorized personnel.
Recent events (2)
- · I (S) $3535
- · Z (S) $5796
1910.147 C04 II
- Issued
- Feb 8, 2019
- Abate by
- May 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: A.) FMC Technologies Measurement Solutions, Inc. - On or about 12/6/18, and at times prior thereto, employees were utilizing lockout procedures for the service of equipment including, but not limited to, Oven 8204. The service on these pieces of equipment included, but were not limited to, repairs and routine preventative maintenance. The lockout procedures utilized were missing information including, but not limited to, identification of all energy sources; the methods used to block mechanical energy sources, and specific steps for testing equipment to verify and determine the effectiveness of lockout devices, tagout devices and other energy control measures.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 333132)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343646667.