OSHA Inspection: G.A. BROWN & SON, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of G.A. BROWN & SON, INC. in 134 S. PENN AVE. RITCHIE COUNTY MIDDLE/HIGH SCHOOL, HARRISVILLE, WV 26362 (NAICS 236220). OSHA activity number 343646816.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G.A. Brown & SON, INC. — free Get an email when a new federal OSHA severe-injury report for G.A. Brown & SON, INC. is published. One employer, no account, unsubscribe in one click.
Site address
134 S. PENN AVE. RITCHIE COUNTY MIDDLE/HIGH SCHOOL
City
HARRISVILLE
State
WV
ZIP
26362
Mailing
215 MILL STREET, FAIRMONT, WV 26554
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
6
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 22, 2019
Abate by
Mar 20, 2019
Penalty
Initial $2,576 · Current $2,189 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.    a.)  Ritchie County Middle/High School, Harrisville WV:  On or about 12/04/18, GFCI protection or an assured grounding program was not provided for the 120 volt Hilti jackhammer.
Recent events (3)
  • — F (S) $2189
  • — C (S) $2576
  • — Z (S) $2576

1926.34 C

Other-than-serious 1 instance 5 exposed
Issued
Feb 22, 2019
Abate by
Mar 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.34(c): Means of egress was not continually maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency.  a.)  Ritchie County Middle/High School:  On or about 12/04/18, the employer made an emergency exit and labeled it but barred it from being in operation.