Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RADIANT STEEL PRODUCTS COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of RADIANT STEEL PRODUCTS COMPANY in 205 LOCUST STREET, WILLIAMSPORT, PA 17701 (NAICS 332322). OSHA activity number 343652160.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Radiant Steel Products Company — free Get an email when a new federal OSHA severe-injury report for Radiant Steel Products Company is published. One employer, no account, unsubscribe in one click.
Site address
205 LOCUST STREET
City
WILLIAMSPORT
State
PA
ZIP
17701
Mailing
205 LOCUST STREET, WILLIAMSPORT, PA 17701
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
8
Ownership type
A

2 citations on file for this inspection.

1910.107 L01

Serious Gravity 1 2 instances 2 exposed
Issued
Feb 15, 2019
Abate by
Mar 8, 2019
Penalty
Initial $1,449 · Current $1,014 Reduced
29 CFR 1910.107(l)(1): Electrical equipment and other sources of ignition did not conform to the requirements of paragraphs (c)(1)(i)-(iv), (8) and (9)(i) of this section and subpart S of this part:  a) Powder coating booth, 120 VAC portable radios at both operator stations were located within 36 inches of a booth opening, and were not approved for the location, on or about December 11, 2018.  b) Powder coating booth, a 120 VAC duplex receptacle installation located at the operator station at the conveyor entrance end of the booth, was located within 36 inches of a booth opening, and was not approved for the location, on or about December 11, 2018.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1014.3
  • — Z (S) $1449

1910.107 L06

Other-than-serious 2 instances 2 exposed
Issued
Feb 15, 2019
Abate by
Mar 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.107(l)(6): Electrostatic hand spraying equipment did not meet the provisions of 29 CFR 1910.107(i) and other subparagraphs of this paragraph when used in powder coating:  a) Powder coating booth, the metal floor of the operator station located at the conveyor entrance end, was covered with cardboard, thus inhibiting or preventing effective grounding of the operator at that component of the booth, on or about December 11, 2018.  ABATEMENT CERTIFICATION REQUIRED