Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: LASALLE BIOENERGY LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LASALLE BIOENERGY LLC in 4915 HIGHWAY 125, URANIA, LA 71480 (NAICS 488510). OSHA activity number 343655262.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lasalle Bioenergy LLC for free Get an email when a new federal OSHA severe-injury report for Lasalle Bioenergy LLC is published. One employer, no account, unsubscribe in one click.
Site address
4915 HIGHWAY 125
City
URANIA
State
LA
ZIP
71480
Mailing
4915 HIGHWAY 125, URANIA, LA 71480
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488510
Employees
100
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C04 II C

Serious Gravity 10 1 instance 5 exposed
Issued
May 14, 2019
Abate by
May 28, 2019
Penalty
Initial $9,282 · Current $9,282
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them.  a) On or about December 13, 2018, at the 310 conveyor, the employer did not ensure that the LOTO procedure included information on the placement and transfer of lockout devices.
Recent events (2)
  • · I (S) $9282
  • · Z (S) $9282

1910.147 C08

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
May 14, 2019
Abate by
May 28, 2019
Penalty
Initial $9,282 · Current $0 Reduced
29 CFR 1910.147(c)(8): Lockout or tagout was not performed only by the authorized employees who are performing the servicing or maintenance:  a) On or about December 13, 2018, at the 310 conveyor, the employer did not ensure that locks were attached by the person/persons performing the work.
Recent events (2)
  • · I (S) $0
  • · Z (S) $9282

1910.147 D04 I

Serious Gravity 10 1 instance 5 exposed
Issued
May 14, 2019
Abate by
May 28, 2019
Penalty
Initial $9,282 · Current $9,282
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    a) On or about December 13, 2018, at the 310 conveyor, locks were not properly and effectively attached to the item/s to be locked out.
Recent events (2)
  • · I (S) $9282
  • · Z (S) $9282

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343655262.