Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: V&P HYDRAULIC PRODUCTS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of V&P HYDRAULIC PRODUCTS, LLC in 1700 PITTSBURGH DRIVE, DELAWARE, OH 43015 (NAICS 333995). OSHA activity number 343656898.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch V&P Hydraulic Products, LLC — free Get an email when a new federal OSHA severe-injury report for V&P Hydraulic Products, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1700 PITTSBURGH DRIVE
City
DELAWARE
State
OH
ZIP
43015
Mailing
1700 PITTSBURGH DRIVE, DELAWARE, OH 43015
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333995
Employees
55
Ownership type
A

4 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 8, 2019
Abate by
Apr 25, 2019
Penalty
Initial $5,635 · Current $5,635
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  a. The employer did not conduct periodic inspections of the energy control procedures at least annually.
Recent events (2)
  • — I (S) $5635
  • — Z (S) $5635

1910.179 J02 III

Other-than-serious 1 instance 55 exposed
Issued
Apr 8, 2019
Abate by
May 13, 2019
Penalty
Initial $5,636 · Current $0 Reduced
29 CFR 1910.179(j)(2): Frequent inspection. The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:    29 CFR 1910.179(j)(2)(iii): Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected. For hooks with cracks or having more than 15 percent in excess of normal throat opening or more than 10�° twist from the plane of the unbent hook refer to paragraph (l)(3)(iii)(a) of this section.    a. Throughout the facility, monthly inspection of overhead crane hooks were not performed and certified.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5636

1910.179 J02 IV

Other-than-serious 1 instance 55 exposed
Issued
Apr 8, 2019
Abate by
May 13, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2): Frequent inspection. The following items shall be inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections. All deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:    29 CFR 1910.179(j)(2)(iv): Hoist chains, including end connections, for excessive wear, twist, distorted links interfering with proper function, or stretch beyond manufacturer's recommendations. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected.      a. Throughout the facility, monthly inspection of overhead crane hoist chains were not performed and certified.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.178 L06

Other-than-serious 1 instance 6 exposed
Issued
Apr 8, 2019
Abate by
May 13, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.  a. At the site, the employer did not certify that each forklift operator was trained and evaluated as required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View V&P Hydraulic Products, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343656898.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.