Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: AMERICAN TUBING INTERNATIONAL

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AMERICAN TUBING INTERNATIONAL in 2191 FORD AVE, SPRINGDALE, AR 72764 (NAICS 332999). OSHA activity number 343657284.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Tubing International — free Get an email when a new federal OSHA severe-injury report for American Tubing International is published. One employer, no account, unsubscribe in one click.
Site address
2191 FORD AVE
City
SPRINGDALE
State
AR
ZIP
72764
Mailing
2191 FORD AVE, SPRINGDALE, AR 72764
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
244
Ownership type
A

3 citations on file for this inspection.

1910.253 D03 VII

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 4, 2019
Abate by
Apr 25, 2019
Penalty
Initial $9,472 · Current $5,683 Reduced
29 CFR 1910.253(d)(3)(vii): Oxygen piping and fittings were not washed out with a suitable solution which would effectively remove grease and dirt but would not react with oxygen:  On or about December 10, 2018 and times prior thereto, the employer did not wash the interior of copper tubing with a solution to effectively remove grease and oil that was being installed to carry industrial grade oxygen to supply the brazing torches in the brazing department. This exposes employees to fire or explosion from oil contamination inside the copper lines supplying oxygen.
Recent events (2)
  • — I (S) $5683.2
  • — Z (S) $9472

1910.253 D03 VIII

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 4, 2019
Abate by
Apr 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.253(d)(3)(viii): For oxygen piping, oil free air, oil free nitrogen, or oil free carbon dioxide was not used for cleaning purposes:  On or about December 10, 2018 and times prior thereto, the employer did not use oil free air to remove foreign material from the new oxygen piping system installed to supply industrial grade oxygen to the brazing torch operator stations in the brazing department.  This exposes employees to the hazard of fire or explosion from oil contamination inside the piping system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 D05 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 4, 2019
Abate by
Apr 25, 2019
Penalty
Initial $9,472 · Current $5,683 Reduced
29 CFR 1910.253(d)(5)(i): The material used for testing oxygen lines was not oil free and noncombustible:  On or about December 10, 2018 and times prior thereto, the employer did not use oil free air to pressure test the copper tubing installed to supply industrial grade oxygen to the brazing torches in the razing department.  This exposes employees to the hazard of fire or explosion.
Recent events (2)
  • — I (S) $5683.2
  • — Z (S) $9472

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343657284.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.