On , OSHA opened a follow-up safety inspection of PALLET 911, LLC in 602 S. INDIANA AVE, BROWNSVILLE, TX 78521 (NAICS 423830). OSHA activity number 343658761.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pallet 911, LLC for free Get an email when a new federal OSHA severe-injury report for Pallet 911, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PALLET 911, LLC
Site address
602 S. INDIANA AVE
City
BROWNSVILLE
State
TX
ZIP
78521
Mailing
602 S. INDIANA AVE, BROWNSVILLE, TX 78521
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423830
Employees
27
Ownership type
Private (A)

3 citations on file for this inspection.

1910.305 G01 IV A

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 12, 2019
Penalty
Initial $9,282 · Current $3,800 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On December 12, 2018, and times prior thereto, in the air pump area, welding leads were energized with a hanging extension cord plug used as a permanent fixed receptacle at a junction box.
Recent events (2)
  • · I (S) $3800
  • · Z (S) $9282

1910.307 C01

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Apr 12, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.307(c)(1): Equipment and associated wiring was not approved as intrinsically safe as permitted in any hazardous location for which it is approved:  On December 12, 2018, and times prior thereto, in the air pump area, an electrical plug was not approved for use in Class II locations where combustible dust was present.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.22 A02

Repeat Gravity 10 1 instance 4 exposed
Issued
Apr 12, 2019
Abate by
May 8, 2019
Penalty
Initial $18,564 · Current $10,000 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    On December 12, 2018, and times prior thereto, throughout the production floor areas the employer did not ensure that the work areas were kept free of escaping combustible dust.    Pallet 911, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.22(a)(2), which was contained in OSHA inspection number 1178368, citation number 01, item number 001 and was affirmed as a final order on 02/01/2017, with respect to a workplace located at 602 S. Indiana Ave., Brownsville, TX  78521.
Recent events (2)
  • · I (R) $10000
  • · Z (R) $18564