OSHA Inspection: DCI, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DCI, INC. in 265 SOUTH MAIN STREET, LISBON, NH 03585 (NAICS 337127). OSHA activity number 343660239.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DCI, INC. — free Get an email when a new federal OSHA severe-injury report for DCI, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DCI, INC.
Site address
265 SOUTH MAIN STREET
City
LISBON
State
NH
ZIP
03585
Mailing
265 SOUTH MAIN STREET, LISBON, NH 03585
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
Employees
150
Ownership type
A

27 citations on file for this inspection.

1910.25 B05 I

Deleted Serious Gravity 1 1 instance 100 exposed
Issued
Apr 3, 2019
Abate by
May 20, 2019
Penalty
Initial $5,115 · Current $0 Reduced
29 CFR 1910.25(b)(5)(i): When a door or gate opens directly on a stairway, a platform was not provided and/or the platform did not provide a useable depth greater or equal to 20 inches:  Rough Mill- Employees were not protected from a trip hazard where the exit door at the back of the rough mill, adjacent to the panel saw, did not have a stair landing.
Recent events (3)
  • — F (S) $0
  • — C (S) $5115
  • — Z (S) $5115

1910.133 A01

Serious Gravity 5 1 instance 50 exposed
Issued
Apr 3, 2019
Abate by
Apr 9, 2019
Penalty
Initial $8,525 · Current $4,000 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation  Location: flammable storage room On or about December 7, 2018, employees were not protected from eye injuries, where a face shield or goggles were not required to be worn to protect from splash hazards, when transferring pre-cat lacquer from 55 gallon drums into 5 gallon buckets for daily use.
Recent events (3)
  • — F (S) $4000
  • — C (S) $8525
  • — Z (S) $8525

1910.133 A03

Serious Gravity 5 1 instance 50 exposed
Issued
Apr 3, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(3): The employer did not ensure that employees wearing prescription lenses while engaged in operations that involve eye hazards wore eye protection that incorporates the prescription in its design or wore eye protection that can be worn over the prescription lenses.  a) Site-  On or about December 7, 2018 employees who wore prescription eye glasses were not protected from eye injuries where safety glasses were not required to be worn over the prescription lenses while operating or working near wood working equipment.  b) Spray booth 'old' and 'new'- On or about December 7, 2018, employees who wore prescription eye glasses or safety glasses in the spray finishing area were not required to wear appropriate eye protection to prevent eye injury from splash and spray hazards while spraying pre-cat lacquer in the spray booths.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.137 C02 VIII

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2019
Abate by
Apr 9, 2019
Penalty
Initial $8,525 · Current $4,000 Reduced
29 CFR 1910.137(c)(2)(viii): Electrical protective equipment was not subjected to periodic electrical tests at intervals in accordance with Table I-4 and Table I-5.  Site- An employee required to conduct voltage testing of live electrical circuits and equipment was not protected from electrical shock where the employer did not have rubber insulating gloves tested every six months as required.
Recent events (3)
  • — F (S) $4000
  • — C (S) $8525
  • — Z (S) $8525

1910.332 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2019
Abate by
Apr 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:   Site- An employee required to conduct voltage testing of live electrical circuits and equipment was not protected from arc flash hazards and burns where the employer did not provide safe electrical work practice training.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 40 instances 10 exposed
Issued
Apr 3, 2019
Abate by
May 20, 2019
Penalty
Initial $8,525 · Current $4,500 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  Site- On or about January 23, 2019, an employee who had not received lock out/tag out training was not protected from an amputation and severe laceration hazard while replacing two cutting heads on the GreCon FDrF 205 600 800 finger joiner where the finger joiner was not deenergized, locked out, or tagged out and the work was done without using alternative measures which provide effective protection.
Recent events (3)
  • — F (S) $4500
  • — C (S) $8525
  • — Z (S) $8525

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  Maintenance Garage- On or about January 23, 2019, two employees were not protected from an amputation and severe laceration hazard while replacing two cutting heads on the GreCon FDrF 205 600 800 finger joiner where the finger joiner was not deenergized, locked out, or tagged out and the work was done without using alternative measures which provide effective protection.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.333 B02 III A

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed:  Site- Employees were not protected from electric shock where a branch circuit, used to feed a wall fan adjacent to the panel saws, was disconnected from the fan and had exposed conductors. The branch circuit was deenergized at its disconnect but a lock and tag was not applied to the disconnect.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.169 B03 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2019
Abate by
Apr 22, 2019
Penalty
Initial $8,525 · Current $3,000 Reduced
29 CFR 1910.169(b)(3)(iv): Safety valve(s) on compressed air receiver(s) were not tested at frequently regular intervals to determine if they were in good operating condition:  Maintenance Garage- Employees working in the garage were not protected from struck by hazards where a Kargard Industries air receiver manufactured in 1986 did not have its safety valve tested within the last 12 months. It was unknown when the last test had occurred.
Recent events (3)
  • — F (S) $3000
  • — C (S) $8525
  • — Z (S) $8525

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2019
Abate by
Apr 29, 2019
Penalty
Initial $8,525 · Current $4,000 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  Site- Each employee who operates powered industrial trucks at the site were not provided with operator training by the employer.
Recent events (3)
  • — F (S) $4000
  • — C (S) $8525
  • — Z (S) $8525

1910.178 L04 III

Serious Gravity 5 1 instance 10 exposed
Issued
Apr 3, 2019
Abate by
Apr 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  Site- Each employee who operates powered industrial trucks at the site were not provided with a performance evaluation every three years.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.178 Q07

Serious Gravity 5 1 instance 11 exposed
Issued
Apr 3, 2019
Abate by
Apr 29, 2019
Penalty
Initial $8,525 · Current $4,000 Reduced
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  Site- The employer did not ensure that each powered industrial truck operated by employees at the site were inspected prior to being placed into service.
Recent events (3)
  • — F (S) $4000
  • — C (S) $8525
  • — Z (S) $8525

1910.212 A01

Serious Gravity 5 5 instances 10 exposed
Issued
Apr 3, 2019
Abate by
Apr 29, 2019
Penalty
Initial $8,525 · Current $4,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a. Rough Mill- Employees operating the quad press were not protected from crushing and amputation hazards where employees place their hands in the point of operation to hold or move material in the press during operation and guards are not in place.    b. Milling- Employees operating the Busellato CNC router, model JET 4000 S/N 4668, were not protected from an amputation and severe laceration hazard where the point of operation was not guarded where the pressure sensing mat on the ground in front of the equipment became disconnected from the equipment when its connecting cord was touched.   c. Milling- An employee operating the CMS CNC router #4, model NCTPF/102-4T4M S/N US004, was not protected from struck by, sever laceration, and amputation hazards where the moving table and point of operation was not guarded.   d. Milling- Employees operating and working near CMS CNC routers #1, 2, and 4 were not protected from severe laceration and amputation hazards where point of operation was not guarded. CMS CNC routers were located next to aisle ways with numerous trip hazards where employees could have fallen into the equipment at the front and sides.
Recent events (3)
  • — F (S) $4500
  • — C (S) $8525
  • — Z (S) $8525

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2019
Abate by
Apr 22, 2019
Penalty
Initial $8,525 · Current $4,500 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  Milling- Employees operating the Gerhard Koch bore and dowel machine, model SBD-B0NC S/N 8910/4071, were not protected from a severe laceration and amputation hazard where pulleys located at waist height were not guarded.
Recent events (3)
  • — F (S) $4500
  • — C (S) $8525
  • — Z (S) $8525

1910.303 B02

Deleted Serious Gravity 5 2 instances 5 exposed
Issued
Apr 3, 2019
Abate by
Apr 22, 2019
Penalty
Initial $8,525 · Current $0 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a. Milling- Employees working from the ground around the double edge bander were not protected from struck by and arc flash hazards where the Square D plug in tap box for the double edge bander was not supported as required by the listing and labeling requirements. The employer was using a ratchet strap to support and secure the tap box in place on the Square D busway.  b. Milling and Shipping- The 480 volt service disconnect #2 milling panel board and two 480 volt panel boards located in the mill near the Koch bore and dowel machine and the shipping area were not installed as required where sheet metal was used to cover openings over missing circuit breakers instead of listed and labeled Square D filler plates.
Recent events (3)
  • — F (S) $0
  • — C (S) $8525
  • — Z (S) $8525

1910.303 F02

Serious Gravity 5 18 instances 100 exposed
Issued
Apr 3, 2019
Abate by
May 20, 2019
Penalty
Initial $8,525 · Current $4,000 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  Rough Mill, Milling, Plywood Area- Employees operating woodworking equipment were not protected from electrical hazards where overcurrent devices, electric disconnects, and panel boards were not marked or legibly marked to indicate its purpose. The following equipment was not legibly marked to indicate its purpose:     1. Electric disconnect for the MJM Gang Saw 2. Electric disconnect for the feed conveyor after the MJM Gang Saw 3. Electric disconnect for the Dimter saw feed conveyor 4. Electric disconnect and control panel for the hammer mill 5. Circuit breakers in the 220 Volt panel board in the rough mill at the end wall by the exit 6. Electric disconnect for the Electro-Flow RF glue machine 7. Circuit breakers in the 480 Service Disconnect #2 panel board in the mill 8. Circuit breakers in two 480 volt panel boards near the Koch bore and dowel machine 9. Two 600 Volt electric disconnects near the Koch bore and dowel machine  10. Circuit breakers in the 208 volt panel board near the panel saws 11. All the Square D Plug-In Tap Boxes along the busways in the Rough Mill, Mill, and Plywood Area 12. Electric disconnect outside compressor room 13. 480 volt electric disconnects in the compressor room 14. Circuit breakers in the 480 volt panel board in the shipping department near the exit 15. Circuit breakers in the 220 volt panel board in the shipping department near the exit 16. 480 volt electric disconnects mounted on the wall outside the maintenance shop 17. Circuit breakers in the 480 volt PP-1 panel board in the maintenance garage 18. 480 volt electric disconnects in the maintenance garage near the finger joiner
Recent events (3)
  • — F (S) $4000
  • — C (S) $8525
  • — Z (S) $8525

1910.305 A02 V C

Serious Gravity 5 1 instance 100 exposed
Issued
Apr 3, 2019
Abate by
Apr 9, 2019
Penalty
Initial $8,525 · Current $4,000 Reduced
29 CFR 1910.305(a)(2)(v)(C): Branch-circuit conductors were laid on the floor.  Shipping Area exterior building exit- Employees entering and exiting the facility were not protected from an electric shock hazard where a 480 volt branch circuit was placed directing on the ground outside the exit to provide power to a temporary air compressor. The 480 volt branch circuit was placed on the ground between the building and compressor where employees walk from the parking lot and step on the branch circuit; which was evident due to the foot prints in the snow.
Recent events (3)
  • — F (S) $4000
  • — C (S) $8525
  • — Z (S) $8525

1910.305 A02 X

Deleted Serious Gravity 5 1 instance 100 exposed
Issued
Apr 3, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points.  Shipping Area exterior building exit- Employees entering and exiting the facility were not protected from an electric shock hazard where a 480 volt branch circuit was run through a concrete wall without any protective conduit and placed directly on the ground outside the exit to service a temporary air compressor. The 480 volt branch circuit was placed on the ground between the building and compressor where employees walk from the parking lot and step on the branch circuit; which was evident due to the foot prints in the snow.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.37 A03

Other-than-serious Gravity 1 1 instance 100 exposed
Issued
Apr 3, 2019
Abate by
May 20, 2019
Penalty
Initial $5,115 · Current $2,500 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  Rough Mill, Milling, Mold Room, Spray Finishing, Assembly- Employees were not protected from a trip hazard where material handling carts were kept in the exit routes.
Recent events (3)
  • — F (O) $2500
  • — C (S) $5115
  • — Z (S) $5115

1910.147 C04 I

Other-than-serious Gravity 5 40 instances 10 exposed
Issued
Apr 3, 2019
Abate by
May 20, 2019
Penalty
Initial $8,525 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in the activities covered by this section:  Site- On or about January 23, 2019, two employees were not protected from an amputation and severe laceration hazard while replacing two cutting heads on the GreCon FDrF 205 600 800 finger joiner where the finger joiner was not deenergized, locked out, or tagged out and the work was done without using alternative measures which provide effective protection.
Recent events (3)
  • — F (O) $0
  • — C (S) $8525
  • — Z (S) $8525

1910.333 B02 I

Other-than-serious Gravity 5 1 instance 1 exposed
Issued
Apr 3, 2019
Abate by
May 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures required in paragraph (b)(2) of 29 CFR 1910.333:  Site- An employee required to make electrical repairs was not protected from electric shock and burns where the employer did not develop and document written procedures for fixed electrical equipment and circuits that are to be deenergized and worked on by the employee.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.303 B01

Other-than-serious Gravity 5 2 instances 25 exposed
Issued
Apr 3, 2019
Abate by
Apr 22, 2019
Penalty
Initial $8,525 · Current $2,500 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  a. Rough Mill- Employees operating the Electro-Flow RF glue machine were not protected from electric shock and burns where the Sorgel 480 volt step down transformer attached to the glue machine was not fully enclosed with the bottom of the transformer completely open.  b. Milling- Employees were not protected from electric shock and fire hazards where wood working equipment not connected to the dust collection system had wood dust accumulated on heat producing electrical equipment. On or about January 23, 2019, the Busellato CNC router, model JET 4000 S/N 4668, had wood dust accumulating on and around the floor mounted transformer servicing the router creating a fire hazard with the heat producing electrical equipment.  c. Rough Mill- Employees operating the gang saw and feed conveyor after the gang saw were not protected from an electric shock hazard where a 480 volt electric feed entering an electric disconnect switch mounted on the conveyor through a conduit was broken and the opening to the disconnect was exposed.  d. Rough Mill- Employees operating the gang saw and feed conveyor after the gang saw were not protected from an electric shock hazard where the foot pedal for an electric lift table was open in the back with the spices from the conductors of the 240 volt connecting cable to control pedal were exposed.
Recent events (3)
  • — F (O) $2500
  • — C (S) $8525
  • — Z (S) $8525

1910.305 G02 III

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Apr 3, 2019
Abate by
Apr 9, 2019
Penalty
Initial $8,525 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:   Rough Mill- Employees operating the gang saw and feed conveyor after the gang saw were not protected from an electric shock hazard where a 240 volt flexible cable connected to a foot pedal for an electric lift table did not have strain relief where the conductors were spliced to the control pedal. The foot pedal was open in the back with the spices from the conductors of the cable to control pedal exposed.
Recent events (3)
  • — F (O) $0
  • — C (S) $8525
  • — Z (S) $8525

1910.304 F01 IV

Other-than-serious Gravity 5 1 instance 100 exposed
Issued
Apr 3, 2019
Abate by
Apr 22, 2019
Penalty
Initial $8,525 · Current $2,500 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:  Site- Employees were not protected from electric shock and burns where Square D Plug-In Tap Boxes connected to overhead busways were not readily available due to materials being stored underneath the overcurrent devices and extension poles used to turn off over currant devices were not readily available in all busway locations.
Recent events (3)
  • — F (O) $2500
  • — C (S) $8525
  • — Z (S) $8525

1910.303 G01 II

Other-than-serious Gravity 5 7 instances 100 exposed
Issued
Apr 3, 2019
Abate by
Apr 22, 2019
Penalty
Initial $8,525 · Current $0 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:  Rough Mill, Milling, Plywood Area- Employees operating woodworking equipment were not protected from electrical hazards where overcurrent devices, electric disconnects, and panel boards were not readily accessible due the working space in front of and below the equipment being used for storage. The electric equipment included the following:  1. 480 volt panel board next to the quad press 2. Two 480 volt panel boards near the Koch bore and dowel machine 3. Two 600 Volt electric disconnects near the Koch bore and dowel machine  4. 208 volt panel board near the panel saws 5. 208 volt fan disconnect next to the panel saws 6. 480 volt PP-1 panel board in the maintenance garage
Recent events (3)
  • — F (O) $0
  • — C (S) $8525
  • — Z (S) $8525

1910.304 B03 II

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2019
Abate by
Apr 9, 2019
Penalty
Initial $8,525 · Current $2,500 Reduced
1910.304(b)(3)(ii)  The following requirements apply to temporary wiring installations that are used during construction-like activities, including certain maintenance, remodeling, or repair activities, involving buildings, structures or equipment. 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  Plywood area- Employees were not protected from an electric shock hazard where an extension cord missing a ground pin was used to provide power to a Sweed Machinery metal band shredding machine. The machine was not double insulated and the electrical receptacle the extension cord was plugged into was not GFCI protected.
Recent events (3)
  • — F (O) $2500
  • — C (S) $8525
  • — Z (S) $8525

1910.305 G02 II

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
Apr 3, 2019
Abate by
Apr 9, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  Plywood area- Employees were not protected from an electric shock hazard where an extension cord used to provide power to a Sweed Machinery metal band shredding machine was spliced together. The splice consisted of two wire nuts on the hot and ground wire and no wire nut on the neutral wire where there was an exposed live conductor.