Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,192,068Inspections Most recent open 2026-08-04 Last loaded 2026-08-07

OSHA Inspection: BRAD'S FUEL FILTERING, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BRAD'S FUEL FILTERING, INC. in 801 BUTLER PIKE, MERCER, PA 16137 (NAICS 562998). OSHA activity number 343662193.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Brad'S Fuel Filtering, INC. for free Get an email when a new federal OSHA severe-injury report for Brad'S Fuel Filtering, INC. is published. One employer, no account, unsubscribe in one click.
Site address
801 BUTLER PIKE
City
MERCER
State
PA
ZIP
16137
Mailing
3515 MARMENCO COURT, BALTIMORE, MD 21230
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562998
Employees
2
Ownership type
A

5 citations on file for this inspection.

1910.28 B01 I

Other-than-serious Gravity 5 1 instance 2 exposed
Issued
May 31, 2019
Abate by
Jun 26, 2019
Penalty
Initial $3,410 · Current $0 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling:   A.)  Brad's Fuel Filtering, Inc., 801 Butler Pike,  Mercer, PA  16137, west side of the prison facility, on or about December 13, 2018 and times prior thereto:  Employees were exposed to a fall hazard of 8.6-feet while working atop a diesel fuel tank.  Employees were not utilizing fall protection.
Recent events (3)
  • · F (O) $0
  • · C (S) $3410
  • · Z (S) $3410

1910.333 C03

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
May 31, 2019
Abate by
Jun 26, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.333(c)(3): When work was to be performed near overhead lines, the lines were not deenergized and grounded, nor were other protective measures provided before work was started:  A.)  Brad's Fuel Filtering, Inc., 801 Butler Pike,  Mercer, PA  16137, west side of the prison facility, on or about December 13, 2018 and times prior thereto:  An employee raised a metal stinger/siphon tube in the air, came into contact/proximity with 14.5-kV overhead powerlines, and was subsequently electrocuted.  The powerlines were not deenergized and grounded, or otherwise provided with protective measures.
Recent events (3)
  • · F (O) $0
  • · C (S) $13260
  • · Z (S) $13260

1910.333 C03 I A 1

Serious Gravity 10 1 instance 1 exposed
Issued
May 31, 2019
Abate by
Jun 26, 2019
Penalty
Initial $0 · Current $6,500
29 CFR 1910.333(c)(3)(i)(A)(1): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below, the location was not such that the person and the longest conductive object he or she could contact cannot come closer to any unguarded energized overhead line:  A.)  Brad's Fuel Filtering, Inc., 801 Butler Pike,  Mercer, PA  16137, west side of the prison facility, on or about December 13, 2018 and times prior thereto:  An employee raised a metal stinger/siphon tube in the air and came into contact/proximity with 14.5-kV overhead powerlines.  The employee was subsequently electrocuted.
Recent events (3)
  • · F (S) $6500
  • · C (S) $0
  • · Z (S) $0

1910.333 C06

Serious Gravity 10 1 instance 1 exposed
Issued
May 31, 2019
Abate by
Jun 26, 2019
Penalty
Initial $0 · Current $6,500
29 CFR 1910.333(c)(6): Conductive materials and equipment that were in contact with an employee's body were not handled in a manner that would prevent them from contacting exposed energized conductors or circuit parts:  A.)  Brad's Fuel Filtering, Inc., 801 Butler Pike,  Mercer, PA  16137, west side of the prison facility, on or about December 13, 2018 and times prior thereto:  An employee raised a metal stinger/siphon tube in the air, came into contact/proximity with 14.5-kV overhead powerlines, and was subsequently electrocuted.
Recent events (3)
  • · F (S) $6500
  • · C (S) $0
  • · Z (S) $0

1910.332 B01

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
May 31, 2019
Abate by
Jul 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments:  A.)  Brad's Fuel Filtering, Inc., 801 Butler Pike,  Mercer, PA  16137, west side of the prison facility, on or about December 13, 2018 and times prior thereto:  An employee raised a metal stinger/siphon tube in the air, came into contact/proximity with 14.5-kV overhead powerlines, and was subsequently electrocuted.  Employees were not provided with specific information regarding the proper distances, methods and techniques to keep conductive objects away from overhead powerlines and components.  In addition, employees were not trained on the requirements noted in standards including, but not limited to, 29 CFR 1910.333(c)(3).  B.)  Brad's Fuel Filtering, Inc., 801 Butler Pike,  Mercer, PA  16137, west side of the prison facility, on or about December 13, 2018 and times prior thereto:  An employee raised a metal stinger/siphon tube in the air, came into contact/proximity with 14.5-kV overhead powerlines, and was subsequently electrocuted.  Employees were not provided with specific information regarding the proper distances, methods and techniques to keep conductive objects away from overhead powerlines and components.  In addition, employees were not trained on the requirements noted in standards including, but not limited to, 29 CFR 1910.333(c)(3)(i)(A)(1).  C.)  Brad's Fuel Filtering, Inc., 801 Butler Pike,  Mercer, PA  16137, west side of the prison facility, on or about December 13, 2018 and times prior thereto:  An employee raised a metal stinger/siphon tube in the air, came into contact/proximity with 14.5-kV overhead powerlines, and was subsequently electrocuted.  Employees were not provided with specific information regarding the proper distances, methods and techniques to keep conductive objects away from overhead powerlines and components.  In addition, employees were not trained on the requirements noted in standards including, but not limited to, 29 CFR 1910.333(c)(6).