NORFOLK, VA ·
OSHA Inspection: ADVANCED INTERNET MARKETING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADVANCED INTERNET MARKETING, INC. in NAVAL STATION NORFOLK U.S.S. MASON, NORFOLK, VA 23523 (NAICS 336611). OSHA activity number 343662300.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED INTERNET MARKETING, INC.
- Site address
- NAVAL STATION NORFOLK U.S.S. MASON
- City
- NORFOLK
- State
- VA
- ZIP
- 23523
- Mailing
- 2696 RELIANCE DR., STE 100, VIRGINIA BEACH, VA 23452
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 80
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1915.89 B
- Issued
- Jan 23, 2019
- Abate by
- Mar 12, 2019
- Penalty
- Initial $6,630 · Current $4,000 Reduced
General-duty citation text
29 CFR 1915.89(b): A written program and procedures for lockout and tags-plus systems to control hazardous energy that included the provisions in 29 CFR 1915.89(b)(1) - (b)(6) was not established and implemented while servicing machinery, equipment or systems: a) Naval Station Norfolk, Norfolk, VA 23511, U.S.S. Mason 5-8-0-T: On or about December 18, 2018, and times prior thereto, the employer did not have a written program for lockout/tags-plus for employees that performed work on the ship's degaussing system with 120VAC and 450VAC electrical energy sources, exposing employees to electrical hazards. Navy ship's force maintained control of the machinery, equipment or systems on the vessel. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $4000
- · Z (S) $6630
1915.12 D05
- Issued
- Jan 23, 2019
- Abate by
- Mar 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1915.12(d)(5): The employer did not certify that the training required by paragraphs (d)(1) through (d)(4) of this section had been accomplished: a) Naval Station Norfolk, Norfolk, VA 23511, U.S.S. Mason 5-8-0-T: On or about December 18, 2018, and times prior thereto, the employer did not certify that each employee received required training prior to confined space entry. Employees performed electrical systems work in a ship's void/confined space that required a Marine Chemist certification prior to entry and hot work, exposing employees to potential atmospheric and other hazards. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.