Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MAUMENEN CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MAUMENEN CONSTRUCTION, INC. in 80 COTTAGE STREET, EAST BOSTON, MA 02128 (NAICS 238170). OSHA activity number 343665105.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Maumenen Construction, INC. — free Get an email when a new federal OSHA severe-injury report for Maumenen Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
80 COTTAGE STREET
City
EAST BOSTON
State
MA
ZIP
02128
Mailing
28 GORDON STREET, SOMERVILLE, MA 02144
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 F07

Serious Gravity 10 1 instance 5 exposed
Issued
Jan 30, 2019
Abate by
Feb 7, 2019
Penalty
Initial $3,978 · Current $1,900 Reduced
29 CFR 1926.451(f)(7): Scaffolds shall be erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.    Location: 80 Cottage St. East Boston, MA, 02128 Exterior of Residential Renovation Project    Employees were exposed to Fall Hazards while applying new siding to a residential structure due to the inadequate, unsafe assembly methods used in an Alum-A-Pole scaffold system and the lack of a Competent Person within the company to ensure adequate, safe assembly of any scaffold systems.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3978

1926.451 C03

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2019
Penalty
Initial $3,978 · Current $0 Reduced
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement:    Location: 80 Cottage St. East Boston, MA, 02128 Exterior of Residential Renovation Project    Employees were exposed to fall hazards  while applying new siding to a residential structure utilizing an Alum-A-Pole scaffold system where the poles were not plumb
Recent events (2)
  • — I (S) $0
  • — Z (S) $3978

1926.452 J02

Serious Gravity 10 3 instances 5 exposed
Issued
Jan 30, 2019
Abate by
Feb 7, 2019
Penalty
Initial $3,978 · Current $0 Reduced
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.    Location: 80 Cottage St. East Boston, MA, 02128 Exterior of Residential Renovation Project    Employees were exposed to Fall Hazards  while applying new siding to a residential structure due to non-secured poles in a Alum-A-Pole scaffold system
Recent events (2)
  • — I (S) $0
  • — Z (S) $3978

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 30, 2019
Penalty
Initial $3,978 · Current $1,900 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).    Location: 80 Cottage St. East Boston, MA, 02128 Exterior of Residential Renovation Project    Employees were exposed to Electrocution Hazards while applying new siding to a residential structure where the pole of the Alum-A-Pole scaffold system was less than 3 feet from the overhead power line.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3978

View Maumenen Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343665105.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.