NAPLES, FL ·
OSHA Inspection: LEYY CARPENTRY INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LEYY CARPENTRY INC. in 1650 CRAYTON ROAD, NAPLES, FL 34102 (NAICS 238130). OSHA activity number 343665576.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEYY CARPENTRY INC.
- Site address
- 1650 CRAYTON ROAD
- City
- NAPLES
- State
- FL
- ZIP
- 34102
- Mailing
- 4748 ESCOBAR AVENUE APARTMENT A, NAPLES, FL 34103
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1903.19 C01
- Issued
- Aug 12, 2019
- Abate by
- Aug 16, 2019
- Penalty
- Initial $319 · Current $319
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 1 issued on 4/26/2019 with an abatement due date of 5/22/2019. b) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 2 issued on 4/26/2019 with an abatement due date of 5/22/2019. c) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 3 issued on 4/26/2019 with an abatement due date of 5/22/2019. d) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 4 issued on 4/26/2019 with an abatement due date of 5/22/2019. e) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 5 issued on 4/26/2019 with an abatement due date of 5/22/2019. f) On or about 07/08/2019, the employer failed to submit certification of corrective action for citation 1, item 6 issued on 4/26/2019 with an abatement due date of 5/02/2019.
Recent events (1)
- · Z (O) $319
1926.451 B01
- Issued
- Apr 26, 2019
- Abate by
- May 22, 2019
- Penalty
- Initial $3,410 · Current $3,410
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, an employee without fall protection was exposed to a fall hazard while working from a hanging bracket scaffold that was not fully planked.
Recent events (1)
- · Z (S) $3410
1926.451 C02
- Issued
- Apr 26, 2019
- Abate by
- May 22, 2019
- Penalty
- Initial $3,410 · Current $3,410
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, an employee without fall protection was exposed to a fall hazard of 16 feet to ground level while working from a hanging bracket scaffold that had wooden uprights on the ground that did not have base plates or mudsills.
Recent events (1)
- · Z (S) $3410
1926.451 E01
- Issued
- Apr 26, 2019
- Abate by
- May 22, 2019
- Penalty
- Initial $3,410 · Current $3,410
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, an employee was not provided with a means to safely access a hanging bracket scaffold, thus exposing the worker to a fall hazard of 16 feet to ground level.
Recent events (1)
- · Z (S) $3410
1926.451 G01
- Issued
- Apr 26, 2019
- Abate by
- May 22, 2019
- Penalty
- Initial $3,410 · Current $3,410
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, an employee without fall protection was exposed to a fall hazard of 16 feet to ground level while working from a hanging bracket scaffold.
Recent events (1)
- · Z (S) $3410
1926.501 B13
- Issued
- Apr 26, 2019
- Abate by
- May 22, 2019
- Penalty
- Initial $3,410 · Current $3,410
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, employees working on a sloped roof with a 4:12 pitch on a residential home in construction and not wearing fall protection, were exposed to a fall hazard of 16 feet to ground level.
Recent events (1)
- · Z (S) $3410
1926.1053 B01
- Issued
- Apr 26, 2019
- Abate by
- May 2, 2019
- Penalty
- Initial $1,705 · Current $1,705
General-duty citation text
29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about 12/13/2018, at 1650 Crayton Road, in Naples, Florida, employees were using a ladder that did not extend at least 3 feet above the landing to access a roof exposing them to a fall hazard.
Recent events (1)
- · Z (S) $1705
More inspections in this industry (NAICS 238130)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343665576.