Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOUNTAINEER GLASS OF CHARLESTON INC.

Follow-up inspection · Safety discipline

On , OSHA opened a follow-up safety inspection of MOUNTAINEER GLASS OF CHARLESTON INC. in 413 DUNBAR AVENUE, DUNBAR, WV 25064 (NAICS 238390). OSHA activity number 343667010.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mountaineer Glass of Charleston INC. — free Get an email when a new federal OSHA severe-injury report for Mountaineer Glass of Charleston INC. is published. One employer, no account, unsubscribe in one click.
Site address
413 DUNBAR AVENUE
City
DUNBAR
State
WV
ZIP
25064
Mailing
413 DUNBAR AVENUE, DUNBAR, WV 25064
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238390
Employees
12
Ownership type
A

5 citations on file for this inspection.

1926.502 D01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2019
Abate by
May 29, 2019
Penalty
Initial $4,168 · Current $0 Reduced
29 CFR 1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:  (a) 400 Capitol St - On or about November 13, 2018, the employer did not use connectors which were drop forged, pressed, or formed steel to connect vertical lifelines to their anchorages, exposing employees to falls of 15 feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $4168
  • — Z (S) $4168

1926.502 D15

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2019
Abate by
May 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.  (a) 400 Capitol St - On or about November 13, 2018, the employees were using a facility-made anchorage which was not designed and used under the supervision of a qualified person, exposing employees to falls of 15 feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 D09

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2019
Abate by
May 29, 2019
Penalty
Initial $4,168 · Current $0 Reduced
29 CFR 1926.502(d)(9): Lanyards and/or vertical lifelines did not have a minimum breaking strength of 5,000 pounds (22.2 kN):  (a) 400 Capitol St - On or about November 13, 2018, the employer did not provide employees installing windows with vertical lifelines with a minimum breaking strength of 5,000 pounds, exposing employees to falls of 15 feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $4168
  • — Z (S) $4168

1926.502 D11

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
May 9, 2019
Abate by
May 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded:  (a) 400 Capitol St - On or about November 13, 2018, the employer did not ensure vertical lifelines used by employees installing windows were protected from cut or abrasions where they were tied to square aluminum tubing, exposing employees to falls of 15 feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.503 A01

Deleted Repeat Gravity 5 1 instance 12 exposed
Issued
May 9, 2019
Abate by
Jun 5, 2019
Penalty
Initial $8,335 · Current $0 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards.   (a) 400 Capitol St - On or about 11/13/18, the employer did not train the employees on the hazards of working from heights and procedures to follow to protect themselves when work at heights of approximately 15 feet above grade.  Mountaineer Glass of Charleston Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA Inspection Number 1315743, Citation Number 1, Item Number 2 b, and was affirmed as a final order on 7/20/2018, with respect to a workplace located at 710 Lee Street East, Charleston, WV.
Recent events (3)
  • — F (R) $0
  • — C (R) $8335
  • — Z (R) $8335

View Mountaineer Glass of Charleston INC.'s full OSHA safety record →