MIAMI BEACH, FL ·
OSHA Inspection: GA & L CONSTRUCTION CORP
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of GA & L CONSTRUCTION CORP in 2000 PARK AVENUE, MIAMI BEACH, FL 33139 (NAICS 238120). OSHA activity number 343671046.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GA & L CONSTRUCTION CORP
- Site address
- 2000 PARK AVENUE
- City
- MIAMI BEACH
- State
- FL
- ZIP
- 33139
- Mailing
- 10229 NW 64TH TERRACE #103, DORAL, FL 33178
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 25
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
1903.19 C01
- Issued
- Jul 7, 2026
- Abate by
- Aug 10, 2026
- Penalty
- Initial $398 · Current $398
Recent events (1)
- · Z (O) $398
1903.19 D01
- Issued
- Jul 7, 2026
- Abate by
- Aug 10, 2026
- Penalty
- Initial $0 · Current $0
Recent events (1)
- · Z (O) $0
1926.20 B02
- Issued
- Jun 11, 2019
- Abate by
- Jul 2, 2020
- Penalty
- Initial $5,304 · Current $500 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): On or about 12/17/2018, at a jobsite located at 2000 Park Avenue, Miami Beach, FL, the employer did not conduct frequent and regular inspections of the job site, exposing employees to fall, struck-by, and impalement hazards. Another contractor had laid plywood floor decking that extended beyond the wooden support beam. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (3)
- · F (S) $500
- · C (S) $5304
- · Z (S) $5304
1926.25 A
- Issued
- Jun 11, 2019
- Abate by
- Jul 2, 2020
- Penalty
- Initial $3,789 · Current $500 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: On or about 12/17/2018, at 2000 Park Avenue, Miami, Florida employees were exposed to slip, trip and fall hazards due to construction debris and building material stored throughout the work floor. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (3)
- · F (S) $500
- · C (S) $3789
- · Z (S) $3789
1926.501 A02
- Issued
- Jun 11, 2019
- Abate by
- Jul 2, 2020
- Penalty
- Initial $13,260 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were to work on, had the strength and structure integrity to support employees safely: On or about 12/17/2018, on the 5th floor level of a 5-story residential building, employees were exposed to a 40-foot fall hazard while performing carpentry and general labor work from a working surface not having the strength and structural integrity to support employees safely. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (3)
- · F (S) $1000
- · C (S) $13260
- · Z (S) $13260
1926.501 B01
- Issued
- Jun 11, 2019
- Abate by
- Jul 2, 2020
- Penalty
- Initial $5,304 · Current $500 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: On or about 12/17/2018, on the 5th floor level of a 5-story residential building, employees were exposed to a 40-foot fall hazard while storing cement block units on plywood deck floor without fall protection equipment. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (3)
- · F (S) $500
- · C (S) $5304
- · Z (S) $5304
1926.503 A01
- Issued
- Jun 11, 2019
- Abate by
- Jul 2, 2020
- Penalty
- Initial $5,304 · Current $500 Reduced
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: On or about 12/17/2018, at 2000 Park Avenue, Miami, Florida, the employer failed to provide fall protection training to employees, exposing employees to a 40 foot fall hazard while storing cement block units on a 5th story plywood deck floor without fall protection equipment. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (3)
- · F (S) $500
- · C (S) $5304
- · Z (S) $5304
1926.701 B
- Issued
- Jun 11, 2019
- Abate by
- Jul 2, 2020
- Penalty
- Initial $5,304 · Current $500 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: On or about 12/17/2018, at 2000 Park Avenue, Miami, Florida the employer failed to ensure employees were not exposed to impalement hazards while working above uncapped rebar. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (3)
- · F (S) $500
- · C (S) $5304
- · Z (S) $5304
1926.1053 B01
- Issued
- Jun 11, 2019
- Abate by
- Jul 2, 2020
- Penalty
- Initial $5,304 · Current $500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: On or about 12/17/2018, at 2000 Park Avenue, Miami, Florida employees were exposed to a 10-foot fall hazard while using the base section of an extension ladder when the side rails did not extend at least 3ft above the upper landing. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (3)
- · F (S) $500
- · C (S) $5304
- · Z (S) $5304
1926.1053 B04
- Issued
- Jun 11, 2019
- Abate by
- Jul 2, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On or about 12/17/2018, at 2000 Park Avenue, Miami, Florida employees were exposed to a 10-foot fall hazard while using the base section of an extension ladder without the fly section attached while accessing the upper landing. PLEASE NOTE: DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 238120)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343671046.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.