FOREST PARK, IL ·
OSHA Inspection: RYSY CONSTRUCTION INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RYSY CONSTRUCTION INCORPORATED in 537 THOMAS AVE., FOREST PARK, IL 60130 (NAICS 238170). OSHA activity number 343671962.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RYSY CONSTRUCTION INCORPORATED
- Site address
- 537 THOMAS AVE.
- City
- FOREST PARK
- State
- IL
- ZIP
- 60130
- Mailing
- 10441 S. 75TH AVE., PALOS HILLS, IL 60465
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 6
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1926.102 A01
- Issued
- Feb 26, 2019
- Abate by
- Mar 4, 2019
- Penalty
- Initial $2,842 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) On December 19, 2018, employees using electrical power saws were not wearing safety glasses, thereby exposing the employees to hazards associated with eye injury. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1400
- · Z (S) $2842
1926.304 F
- Issued
- Feb 26, 2019
- Abate by
- Mar 4, 2019
- Penalty
- Initial $2,842 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed ripsaws were not guarded by an automatically adjusting hood which completely encloses that portion of the saw above the table and above the material being cut: a) On December 18, 2018, a Dewalt table saw was not equipped with a blade guard when used to rip lumber. b) On December 18, 2018, a Rigid miter saw was not equipped with a blade guard when used to rip lumber. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1400
- · Z (S) $2842
1926.304 F
- Issued
- Feb 26, 2019
- Abate by
- Mar 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(f): Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) On December 18, 2018, a Dewalt table saw was not equipped with a spreader when used to rip lumber. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.304 F
- Issued
- Feb 26, 2019
- Abate by
- Mar 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(f): Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) On December 18, 2018, a Dewalt table saw was not equipped with non-kickback fingers or dogs when used to rip lumber. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 G01
- Issued
- Feb 26, 2019
- Abate by
- Mar 4, 2019
- Penalty
- Initial $3,978 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: a) On December 19, 2018, employees working from pump-jack scaffolding were exposed to fall hazards of approximately 17 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $2000
- · Z (S) $3978
1926.501 B13
- Issued
- Feb 26, 2019
- Abate by
- Mar 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On December 19, 2018, employees performing siding work were exposed to fall hazards of approximately 14 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.405 B02
- Issued
- Feb 26, 2019
- Abate by
- Mar 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) On or about December 19, 2018, employees were exposed to the electrical hazards where electrical outlets did not have covers exposing them to accidental contact with live parts. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET
Recent events (2)
- · I (O) $0
- · Z (O) $0
1926.503 B01
- Issued
- Feb 26, 2019
- Abate by
- Mar 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a) On or about December 19, 2018, the employer did not maintain records or certification of fall protection training for employees exposed to fall hazards. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238170)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343671962.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.