OSHA Inspection: J & R ROOFING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of J & R ROOFING, LLC in 379 WESTPORT AVE., NORWALK, CT 06851 (NAICS 238160). OSHA activity number 343677712.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & R Roofing, LLC — free Get an email when a new federal OSHA severe-injury report for J & R Roofing, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
J & R ROOFING, LLC
Site address
379 WESTPORT AVE.
City
NORWALK
State
CT
ZIP
06851
Mailing
19 SOUNDVIEW AVE., NORWALK, CT 06854
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 4 exposed
Issued
Mar 5, 2019
Abate by
Mar 18, 2019
Penalty
Initial $319 · Current $319
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   Location: 379 Westport Avenue, Norwalk, CT  06851  Abatement certification and verification for Citation 01, Item 001a; Citation 01, Item 001b; Citation 01, Item 002a; Citation 01, Item 002b; and Citation 001, Item 002c with a Final Order Date of February 11, 2019 were not received within 10 calendar days (February 18, 2019) following the abatement due date of February 8, 2019.
Recent events (1)
  • — Z (O) $319

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 14, 2019
Abate by
Feb 8, 2019
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b).  Worksite: The employer did not ensure that the employees required to work on the residential roof were protected from fall hazards above 6 feet by the use of guardrails, safety nets or personal fall arrest systems.
Recent events (1)
  • — Z (S) $3880

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 14, 2019
Abate by
Feb 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards.  Worksite: The employer did not ensure that the employees exposed to fall hazards while working on the roof at a height above 6 feet were trained in fall hazards and the procedures to be followed to minimize such hazards.
Recent events (1)
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 14, 2019
Abate by
Feb 8, 2019
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed.  Worksite: The employer did not ensure that the 6-foot stepladder used by employees to gain access to the roof was used as it was designed.
Recent events (1)
  • — Z (S) $2772

1926.1053 B06

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 14, 2019
Abate by
Feb 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level.  Worksite: The employer did not ensure that the 6-foot stepladder used by employees to gain access to the roof was placed on a level and stable surface.
Recent events (1)
  • — Z (S) $0

1926.1060 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 14, 2019
Abate by
Feb 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a)(1): The employer did not ensure that each employee was trained by a competent person which would enable each employee to recognize hazards related to ladders and stairs, and the procedures to follow to minimize those hazards.  Worksite: The employer did not ensure that the employees required to use the 6-foot stepladder to gain access to the roof were trained by a competent person in the proper procedures to minimize the hazards associated with ladders.
Recent events (1)
  • — Z (S) $0

View J & R Roofing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343677712.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.