AUSTIN, TX ·
OSHA Inspection: B-TEXAS MULCH, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of B-TEXAS MULCH, LLC in 15307 STORM DR., AUSTIN, TX 78734 (NAICS 321999). OSHA activity number 343678868.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- B-TEXAS MULCH, LLC
- Site address
- 15307 STORM DR.
- City
- AUSTIN
- State
- TX
- ZIP
- 78734
- Mailing
- 15307 STORM DR., AUSTIN, TX 78734
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 1
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jan 25, 2019
- Penalty
- Initial $1,705 · Current $853 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about January 11th, 2019 and times prior thereto, employee was using a front end loader to pour mulch product onto a grinder (Make: Vermeer; Model: HG4000; Serial: 1VRC312H4D1000113). The grinder had the thrown object deflector in a non-operating position, exposing employees to the hazard of being struck by product being ejected from the grinder.
Recent events (2)
- · I (S) $852.5
- · Z (S) $1705
1910.1200 E01
- Issued
- Jan 25, 2019
- Abate by
- Mar 31, 2019
- Penalty
- Initial $1,705 · Current $853 Reduced
D150
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about December 21st, 2018, the employer did not develop or implement a written hazard communication program for employees required to refuel heavy equipment, exposing employee to inhalation and absorption hazards of diesel fuel, additives and/or other chemicals. Required program elements that were not developed and implemented include but are not limited to the following: 1910.1200(e)(1)(i): developing an inventory list of chemicals used in the workplace, 1910.1200(g): Maintaining copies of Safety data sheets (SDS), 1910.1200(h): Providing information and training to employees regarding the hazards of chemicals.
Recent events (2)
- · I (S) $852.5
- · Z (S) $1705
More inspections in this industry (NAICS 321999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343678868.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.