ORLANDO, FL —
OSHA Inspection: UNIVERSAL ENGINEERING SCIENCES, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of UNIVERSAL ENGINEERING SCIENCES, INC. in 14900 CHELONIA PKWY, ORLANDO, FL 32821 (NAICS 541380). OSHA activity number 343679593.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSAL ENGINEERING SCIENCES, INC.
- Site address
- 14900 CHELONIA PKWY
- City
- ORLANDO
- State
- FL
- ZIP
- 32821
- Mailing
- 3532 MAGGIE BOULEVARD, ORLANDO, FL 32811
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541380
- Employees
- 100
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.703 A02
- Issued
- Feb 28, 2019
- Abate by
- Apr 16, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1926.703(a)(2): Drawings or plans, including all revisions, for the jack layout, formwork (including shoring equipment), working decks, and scaffolds were not available at the jobsite: a) At the site located at 14900 Chelonia Pkwy, Orlando FL 32821, the employer used outdated drawings for embedding bolts and brackets into shear wall (21) and without approval from the shoring engineer and the structural engineer of record, on or about August 29, 2018.
Recent events (2)
- — I (S) $0
- — Z (S) $13260
1926.703 B01
- Issued
- Feb 28, 2019
- Abate by
- Apr 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.703(b)(1): Shoring equipment (including equipment used in reshoring operations) was not inspected prior to erection to determine that the equipment met the requirements specified in the formwork drawings: a) At the site located at 14900 Chelonia Pkwy, Orlando, FL 32821, the employer did not perform adequate inspections to recognize and correct the use of bolts and brackets being embedded in the shear wall (21). The use of bolts and brackets and not the approved shoring towers that the sealed engineering shoring drawings require, created a collapse hazard of the 7th floor, on or about August 29, 2018.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Universal Engineering Sciences, INC.
View Universal Engineering Sciences, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 541380)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343679593.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.