Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: R&V BUILDERS, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of R&V BUILDERS, LLC. in 1730 RIDGE AVENUE, PHILADELPHIA, PA 19130 (NAICS 238110). OSHA activity number 343681128.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R&V Builders, LLC. for free Get an email when a new federal OSHA severe-injury report for R&V Builders, LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
R&V BUILDERS, LLC.
Site address
1730 RIDGE AVENUE
City
PHILADELPHIA
State
PA
ZIP
19130
Mailing
2600 EAST CUMBERLAND STREET, PHILADELPHIA, PA 19125
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238110
Employees
14
Ownership type
Private (A)

5 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 9 exposed
Issued
Jun 19, 2019
Penalty
Initial $5,304 · Current $5,304
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury:  a) 1730 Ridge Avenue: The employer failed to eliminate hazards or to instruct the employees who were working in an excavation without any protective system in place, a safe means of egress, and impalement hazards, and ways to avoid the unsafe work conditions.  Condition was observed on or about 21 DEC 2018.
Recent events (1)
  • · Z (S) $5304

1926.651 C02

Serious Gravity 10 1 instance 9 exposed
Issued
Jun 19, 2019
Penalty
Initial $5,304 · Current $5,304
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees:  a) 1730 Ridge Avenue: Employer did not ensure that a safe means of egress was provided within 25 feet of lateral travel for employees working in the excavation; thus exposing employees to various hazards associated with not being able to safely egress from an excavation in case of an emergency.   Condition was noted on or about 21 DEC 2018.
Recent events (1)
  • · Z (S) $5304

1926.651 K01

Serious Gravity 10 1 instance 9 exposed
Issued
Jun 19, 2019
Penalty
Initial $5,304 · Current $5,304
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems was not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions.   a) 1730 Ridge Avenue: The excavation was not inspected by a competent person for protective systems and other hazardous conditions.   Condition was observed on or about 21 FEB 2018.
Recent events (1)
  • · Z (S) $5304

1926.651 K02

Serious Gravity 10 1 instance 9 exposed
Issued
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.651(k)(2): Where the competent person finds evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees shall be removed from the hazardous area until the necessary precautions have been taken to ensure their safety.  a) 1730 Ridge Avenue: The employer did not ensure that deficiencies with the excavation were corrected by a qualified competent person; thus exposing employees to struck-by and caught in-between hazards.  Condition was observed on or about 21 DEC 2018.
Recent events (1)
  • · Z (S) $0

1926.652 A01

Willful Gravity 10 1 instance 9 exposed
Issued
Jun 19, 2019
Penalty
Initial $53,039 · Current $53,039
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):  a) 1730 Ridge Avenue : The employer did not ensure that a protective system was installed inside an excavation that was approximately 11 feet deep, 17 feet wide and 55 feet long to protect the employees from cave-in hazards.   Condition was observed on or about 21 DEC 2018.
Recent events (1)
  • · Z (W) $53039

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343681128.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.