CORPUS CHRISTI, TX ·
OSHA Inspection: BRANDON WELDING AND FABRICATION, INC.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of BRANDON WELDING AND FABRICATION, INC. in 9002 LEOPARD STREET, CORPUS CHRISTI, TX 78409 (NAICS 811310). OSHA activity number 343682829.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRANDON WELDING AND FABRICATION, INC.
- Site address
- 9002 LEOPARD STREET
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78409
- Mailing
- PO BOX 260247, CORPUS CHRISTI, TX 78426
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 14
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.134 E01
- Issued
- Feb 8, 2019
- Penalty
- Initial $2,273 · Current $2,273
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: At this establishment, employees wore elastomeric, half-face, negative-pressure, tight-fitting respirators without first undergoing a medical evaluation.
Recent events (1)
- · Z (S) $2273
1910.134 F01
- Issued
- Feb 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): At this establishment, employees wore elastomeric, half-face, negative-pressure, tight-fitting respirators prior to being fit tested to wear the respirators.
Recent events (1)
- · Z (S) $0
1910.134 K06
- Issued
- Feb 8, 2019
- Abate by
- Mar 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: At this establishment, employees wore elastomeric, half-face, negative-pressure, tight-fitting respirators. The employer did not provide the information contained in Appendix D to the employees.
Recent events (1)
- · Z (S) $0
1910.305 D02
- Issued
- Feb 8, 2019
- Penalty
- Initial $1,932 · Current $1,932
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures approved for the purpose and were not dead front: At this workshop, the LP-4 electrical panel did not have a dead front, exposing employees to live conductors.
Recent events (1)
- · Z (S) $1932
1910.305 B01 II
- Issued
- Feb 8, 2019
- Penalty
- Initial $212 · Current $212
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: At this facility, unused openings in electrical equipment were discovered in the overflow area on the southeast side of the shop in the following instances: a. Right side of #6 MIG Welding Machine Square D safety switch box; and, b. Front panel of the electrical breaker box labeled LP-4 / VIA LDP-1 / CKT #1-3-5. Brandon Welding and Fabrication, Inc. was previously cited for a violation of this Occupational Safety and Health standard which was contained in OSHA inspection number 1233029, citation number 1, item number 2 and was affirmed as a final order on August 17, 2017, with respect to a workplace located at 9002 Leopard Street, Corpus Christi, Texas 78409.
Recent events (1)
- · Z (R) $212
More inspections at Brandon Welding and Fabrication, INC.
View Brandon Welding and Fabrication, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 811310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343682829.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.