Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRANDON WELDING AND FABRICATION, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of BRANDON WELDING AND FABRICATION, INC. in 9002 LEOPARD STREET, CORPUS CHRISTI, TX 78409 (NAICS 811310). OSHA activity number 343682829.

Watch Brandon Welding AND Fabrication, INC. — free Get an email when a new federal OSHA severe-injury report for Brandon Welding AND Fabrication, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9002 LEOPARD STREET
City
CORPUS CHRISTI
State
TX
ZIP
78409
Mailing
PO BOX 260247, CORPUS CHRISTI, TX 78426
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
14
Ownership type
A

5 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  At this establishment, employees wore elastomeric, half-face, negative-pressure, tight-fitting respirators without first undergoing a medical evaluation.
Recent events (1)
  • — Z (S) $2273

1910.134 F01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  At this establishment, employees wore elastomeric, half-face, negative-pressure, tight-fitting respirators prior to being fit tested to wear the respirators.
Recent events (1)
  • — Z (S) $0

1910.134 K06

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:   At this establishment, employees wore elastomeric, half-face, negative-pressure, tight-fitting respirators.  The employer did not provide the information contained in Appendix D to the employees.
Recent events (1)
  • — Z (S) $0

1910.305 D02

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $1932.00 · Current $1932.00
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures approved for the purpose and were not dead front:  At this workshop, the LP-4 electrical panel did not have a dead front, exposing employees to live conductors.
Recent events (1)
  • — Z (S) $1932

1910.305 B01 II

Repeat 2 instances 4 exposed
Issued
Penalty
Initial $212.00 · Current $212.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  At this facility, unused openings in electrical equipment were discovered in the overflow area on the southeast side of the shop in the following instances:  a.  Right side of #6 MIG Welding Machine Square D safety switch box; and, b.  Front panel of the electrical breaker box labeled LP-4 / VIA LDP-1 / CKT #1-3-5.  Brandon Welding and Fabrication, Inc. was previously cited for a violation of this Occupational Safety and Health standard which was contained in OSHA inspection number 1233029, citation number 1, item number 2 and was affirmed as a final order on August 17, 2017, with respect to a workplace located at 9002 Leopard Street, Corpus Christi, Texas 78409.
Recent events (1)
  • — Z (R) $212

View BRANDON WELDING AND FABRICATION, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343682829.