Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UH STRUCTURES, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of UH STRUCTURES, INC. in 2241 INDUSTRIAL DRIVE, CONNELLSVILLE, PA 15425 (NAICS 332311). OSHA activity number 343696712.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch UH Structures, INC. — free Get an email when a new federal OSHA severe-injury report for UH Structures, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
UH STRUCTURES, INC.
Site address
2241 INDUSTRIAL DRIVE
City
CONNELLSVILLE
State
PA
ZIP
15425
Mailing
2241 INDUSTRIAL DRIVE, CONNELLSVILLE, PA 15425
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
17
Ownership type
A

7 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 20, 2019
Abate by
Apr 24, 2019
Penalty
Initial $3,789 · Current $3,789

Hazardous substances 8111

29 CFR 1910.95(c)(1):   A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8-hour time-weighted average sound level (TWA) of 85 dBA:  a)  In the Facility, on or about January 18, 2019 - The employer did not institute a continuing effective hearing conservation program when employee noise exposures exceeded an 8-hour time-weighted average sound level of 85 dBA.  An employee designated as a laborer was exposed to noise at a level of 69.1% of the allowable limit during a 330 minute sampling period on February 13, 2019.   This exposure is equivalent to a sound level of 87.3 dBA for the dose and time of employee exposure and is 1.38 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.  b)  In the Facility, on or about January 18, 2019 - An employee designated as a welder was exposed to noise at a level of 67.3% of the allowable limit during a 336 minute sampling period on February 13, 2019.   This exposure is equivalent to a sound level of 87.1 dBA for the dose and time of employee exposure and is 1.35 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.  c)  In the Facility, on or about January 18, 2019 - An employee designated as a welder/fabricator was exposed to noise at a level of 55.2% of the allowable limit during a 331 minute sampling period on February 13, 2019.   This exposure is equivalent to a sound level of 85.7 dBA for the dose and time of employee exposure and is 1.1 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.
Recent events (1)
  • — Z (S) $3789

1910.95 G01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 20, 2019
Abate by
Apr 24, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:  a)  In the Facility, on or about January 18, 2019 - The employer did not establish and maintain an audiometric testing program for employees whose noise exposures equaled or exceeded an 8-hour time-weighted average noise exposure of 85 decibels.  (See descriptions of employee noise exposures in Citation 1, Item 1a, Instances a-c).
Recent events (1)
  • — Z (S) $0

1910.95 K01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 20, 2019
Abate by
Apr 24, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k):   a)  In the Facility, on or about January 18, 2019 - The employer did not provide noise training to employees whose noise exposures equaled or exceeded an 8-hour time-weighted average noise exposure of 85 decibels.  (See descriptions of employee noise exposures in Citation 1, Item 1a, Instances a-c).
Recent events (1)
  • — Z (S) $0

1910.95 L01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 20, 2019
Abate by
Apr 24, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(l)(1): The employer did not make available to affected employees or their representatives copies of 29 CFR 1910.95 and did not post a copy in the workplace:   a)  In the Facility, on or about January 18, 2019 - The employer did not make a copy of 29 CFR 1910.95, the Occupational Noise Standard, to employees and did not post a copy in the workplace.
Recent events (1)
  • — Z (S) $0

1910.134 K06

Other-than-serious 1 instance 3 exposed
Issued
Mar 20, 2019
Abate by
Apr 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  a)  In the Facility, on or about January 8, 2019 - The employer did not provide the basic advisory information on respirators, Appendix D of 29 CFR 1910.134, to employees who use dust masks voluntarily at the workplace.
Recent events (1)
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 1 exposed
Issued
Mar 20, 2019
Abate by
Apr 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   a)  In the Facility, on or about January 8, 2019 - The employer did not conduct an annual inspection to ensure that the energy control procedures are being followed.  Employees lockout pieces of equipment including but not limited to radial arm saws, panel saws and air compressors.
Recent events (1)
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 10 exposed
Issued
Mar 20, 2019
Abate by
Apr 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a)  In the Facility, on or about January 8, 2019 - The employer did not provide information and training on the updated hazard communication standard, including but not limited to new labeling elements and safety data sheet format.
Recent events (1)
  • — Z (O) $0

View UH Structures, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343696712.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.