Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HOLOGIC, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of HOLOGIC, INC. in 36 APPLE RIDGE ROAD, DANBURY, CT 06810 (NAICS 334517). OSHA activity number 343699120.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hologic, INC. — free Get an email when a new federal OSHA severe-injury report for Hologic, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
HOLOGIC, INC.
Site address
36 APPLE RIDGE ROAD
City
DANBURY
State
CT
ZIP
06810
Mailing
250 CAMPUS DRIVE, MARLBOROUGH, MA 01752
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334517
Employees
350
Ownership type
A

5 citations on file for this inspection.

1910.333 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 10, 2019
Penalty
Initial $13,260 · Current $18,933
29 CFR 1910.333(a)(1): Live parts to which an employee was exposed were not deenergized before the employee worked on or near them:    ESTABLISHMENT:  The BB1 machine was not deenergized and lockout while an employee was performing assembly of a prototype machine to install a power distribution box into the machine.    On or about 12/14/2018, an employee inserting a power distribution box unevenly came in contact with the backwall resulting in a short circuit and an employee sustaining an electrical shock.
Recent events (2)
  • — I (S) $18933
  • — Z (S) $13260

1910.333 B02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 10, 2019
Abate by
Jul 5, 2019
Penalty
Initial $11,366 · Current $0 Reduced
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333.    ESTABLISHMENT:  The employer neither maintained, nor made available a written lockout and tagout procedure for the employees required to work with and handle machines, such as (but not limited to) BB1.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11366

1910.333 B02 III

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 10, 2019
Abate by
Jul 5, 2019
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1910.333(b)(2)(iii): A lock and a tag was not placed on each disconnecting means used to de-energize circuits and equipment on which work was to be performed, except as provided in paragraphs (b)(2)(iii)(C) and (b)(2)(iii)(E) of this section:    ESTABLISHMENT:  The employer did not ensure through maintaining specific instructions and/or visual observation that a lock and a tag was placed on disconnecting means of the BB1 machine prior to allowing employees to manually assemble a prototype machine to install a power distribution box into the machine.    On or about 12/14/2018, an employee inserting a power distribution box unevenly came in contact with the backwall resulting in a short circuit and an employee sustaining an electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13260

1910.332 B01

Other-than-serious 1 instance 1 exposed
Issued
Jun 10, 2019
Penalty
Initial $9,472 · Current $18,933
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments.    ESTABLISHMENT:  The employee manually assembling a prototype machine was not provided with training and information pertaining to the safety-related work practices.
Recent events (2)
  • — I (O) $18933
  • — Z (S) $9472

1910.332 B02

Other-than-serious 1 instance 2 exposed
Issued
Jun 10, 2019
Penalty
Initial $11,366 · Current $0 Reduced
29 CFR 1910.332(b)(2): Additional requirements for unqualified persons. Employees covered by paragraph (a) of this section, but who were not qualified persons, were not trained in and familiar with any electrically related safety practices that were not specifically addressed by 1910.331 through 1910.335 but were necessary for their safety.    ESTABLISHMENT:  The unqualified employee manually assembling a prototype machine was not trained and familiar with any electrically related safety practices that needed to work safely at all times.
Recent events (2)
  • — I (O) $0
  • — Z (S) $11366

View Hologic, INC.'s full OSHA safety record →