AUSTIN, TX —
OSHA Inspection: HANGER PROSTHETICS AND ORTHOTICS WEST, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HANGER PROSTHETICS AND ORTHOTICS WEST, INC. in 8000 ANDERSON SQUARE SUITE 301A, AUSTIN, TX 78757 (NAICS 339113). OSHA activity number 343701835.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HANGER PROSTHETICS AND ORTHOTICS WEST, INC.
- Site address
- 8000 ANDERSON SQUARE SUITE 301A
- City
- AUSTIN
- State
- TX
- ZIP
- 78757
- Mailing
- 10910 DOMAIN DRIVE SUITE 300, AUSTIN, TX 78758
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339113
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.134 C02 II
- Issued
- Feb 13, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $5,683 · Current $2,842 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (a) Employees were permitted to use their own personally purchased elastomeric respirators, and the employer took no steps to ensure that employees were medically able to use the respirators. (b) Employees were permitted to store their voluntarily worn elastomeric respirators uncovered and hanging off of objects in the lab workshop area. This exposed respirators to airborne particulate resulting from grinding and cutting of carbon fiber and epoxy resin done in the area, which could accumulate on the inside of the masks and negatively affect employee health. (c) No policy, schedule, or system was implemented in order to ensure that voluntarily worn elastomeric respirators were cleaned or maintained. This exposed employees to airborne particulate resulting from grinding and cutting of carbon fiber and epoxy resin done in the area, which could accumulate on the inside of the masks and negatively affect employee health. On or about January 9th, 2019, the employer had not ensured that employees were medically able to use voluntarily worn respirators. The employer also did not ensure proper storage, cleaning, or maintenance of the respirators.
Recent events (2)
- — I (O) $2841.5
- — Z (S) $5683
1910.134 K06
- Issued
- Feb 13, 2019
- Abate by
- Feb 26, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) Employees were permitted to use their own personally supplied respirators. Employees were not provided the information contained in 29 CFR 1910.134 Appendix D, made aware of its existence, or trained on its contents. On or about January 9th, 2019, the employer had not provided the basic advisory information on respirators to employees voluntarily wearing respirators in the lab workshop area.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.157 E03
- Issued
- Feb 13, 2019
- Abate by
- Feb 26, 2019
- Penalty
- Initial $5,683 · Current $3,410 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: (a) In the lab, outside of the grinding room. (b) At the lab entrance hallway. (c) In the main office community area. On or about January 9th, 2019 and times prior thereto, fire extinguishers were found onsite that had not been inspected in over 1 year. This condition exposed employees to potential fire hazards.
Recent events (2)
- — I (S) $3409.8
- — Z (S) $5683
More inspections at Hanger Prosthetics and Orthotics West, INC.
View Hanger Prosthetics and Orthotics West, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339113)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343701835.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.