2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: PALMER MANUFACTURING

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PALMER MANUFACTURING in 1 2ND STREET, PEABODY, MA 01960 (NAICS 336412). OSHA activity number 343702338.

Watch Palmer Manufacturing — free Get an email when a new federal OSHA severe-injury report for Palmer Manufacturing is published. One employer, no account, unsubscribe in one click.
Site address
1 2ND STREET
City
PEABODY
State
MA
ZIP
01960
Mailing
1 2ND STREET, PEABODY, MA 01960
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336412
Employees
135
Ownership type
A

6 citations on file for this inspection.

1910.106 E06 II

Serious Gravity 10 3 instances 30 exposed
Issued
Abate by
Penalty
Initial $13127.00 · Current $6000.00 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected.      1 2nd Street, Peabody, MA 01960, Main shop floor.     a) On or about January 7, 2019, employees transferred a category 2 flammable liquid, reagent grade isopropyl alcohol, from a drum, to a plastic bucket, to a wash tank. The containers were not electrically interconnected during dispensing.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $13127

1910.1200 H03 III

Serious Gravity 10 3 instances 30 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from chemical hazards, including specific procedures the employer had implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used:  1 2nd Street, Peabody, MA, Main shop floor.   a) On or about January 7, 2019, employees were not trained in measures to protect themselves from flammable liquid hazards when filling or draining part wash tanks that contain isopropyl alcohol.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5626.00 · Current $1500.00 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    1 2nd Street, Peabody, MA. Tool Crib.     a) On or about June 11, 2019, an employee that was voluntarily wearing a tight fitting half face respirator was not provided a medical evaluation to determine whether or not the employee had the ability to wear a respirator.
Recent events (2)
  • — I (O) $1500
  • — Z (S) $5626

1910.303 B02

Other-than-serious 1 instance 9 exposed
Issued
Abate by
Penalty
Initial $9377.00 · Current $3000.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    1 2nd Street, Main shop floor.     a) On or about January 7, 2019, employees were exposed to fire and explosion hazards from a dust collection booth that was not listed and labeled for the purpose of collecting aluminum dust. Parts deburred in this booth contain aluminum.
Recent events (2)
  • — I (O) $3000
  • — Z (S) $9377

1910.132 D02

Other-than-serious 1 instance 30 exposed
Issued
Abate by
Penalty
Initial $1052.00 · Current $500.00 Reduced
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed:      1 2nd Street, Peabody, MA, Main shop floor.    a) On or about January 7, 2019, the employer did not verify that a workplace hazard assessment for tasks that may necessitate the use of personal protective equipment was conducted. Personal protective equipment was provided to employees, however, the employer did not verify that the assessment was completed.
Recent events (2)
  • — I (O) $500
  • — Z (O) $1052

1910.134 K06

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1052.00 · Current $500.00 Reduced
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:    1 2nd Street, Peabody, MA. Deburring.     a) On or about June 24, 2019, basic advisory information on respirators as presented in Appendix D was not presented to an employee wearing a loose-fitting dust mask type respirator.