Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MIZKAN AMERICA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MIZKAN AMERICA, INC. in 4647 BRONZE WAY, DALLAS, TX 75236 (NAICS 311941). OSHA activity number 343703591.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mizkan America, INC. — free Get an email when a new federal OSHA severe-injury report for Mizkan America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4647 BRONZE WAY
City
DALLAS
State
TX
ZIP
75236
Mailing
4647 BRONZE WAY, DALLAS, TX 75236
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311941
Employees
47
Ownership type
A

2 citations on file for this inspection.

1910.147 C02 III

Other-than-serious 1 instance 2 exposed
Issued
May 2, 2019
Abate by
May 29, 2019
Penalty
Initial $9,282 · Current $4,200 Reduced
29 CFR 1910.147(c)(2)(iii): After January 2, 1990, whenever replacement or major repair, renovation or modification of a machine or equipment is performed, and whenever new machines or equipment are installed, energy isolating devices for such machine or equipment was not designed to accept a lockout device:    (a) This violation occurred on or about January 09, 2019, at a workplace located at 4647 Bronze Way, Dallas, TX in the production department, where the Combi Case Packer, EQ #21001, DP1080035699 was not retrofitted to accept a lockout device.
Recent events (2)
  • — I (O) $4200
  • — Z (S) $9282

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
May 2, 2019
Abate by
May 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed:    (a)   This violation occurred on or about January 09, 2019, at a workplace located at 4647 Bronze Way, Dallas, TX; where the employer did not conduct a periodic inspection of the energy control procedures for the Combi Case Packer.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View Mizkan America, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343703591.