HOUSTON, TX ·
OSHA Inspection: SERAMPORE INDUSTRIES
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SERAMPORE INDUSTRIES in 2900 PATIO DRIVE, HOUSTON, TX 77017 (NAICS 423510). OSHA activity number 343703898.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SERAMPORE INDUSTRIES
- Site address
- 2900 PATIO DRIVE
- City
- HOUSTON
- State
- TX
- ZIP
- 77017
- Mailing
- 2900 PATIO DRIVE, HOUSTON, TX 77017
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 22
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.107 B05 I
- Issued
- May 1, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $9,282 · Current $5,569 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms, or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained: a) At the facility, where the powder coating booth was not equipped with gauges or alarms.
Recent events (2)
- · I (S) $5569
- · Z (S) $9282
1910.107 B05 IV
- Issued
- May 1, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $9,282 · Current $5,569 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: a) At the facility, where the powder coating booth was not equipped with automatic sprinklers on the downstream and upstream sides of the filters.
Recent events (2)
- · I (S) $5569
- · Z (S) $9282
1910.107 D03
- Issued
- May 1, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $7,956 · Current $4,773 Reduced
General-duty citation text
29 CFR 1910.107(d)(3): The spray booth did not have an independent exhaust duct system discharging to the exterior of the building. a) At the facility, where the powder coating booth exhaust system discharged into the interior of the building.
Recent events (2)
- · I (S) $4773
- · Z (S) $7956
1910.134 C01
- Issued
- May 1, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $7,956 · Current $4,773 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) At the facility, where the employer had not implemented a respiratory protection program prior to the use of half-face elastomeric respirators. Employees used half-face respirators during powder coating activities. b) At the facility, where the employer had not implemented a respiratory protection program prior to the use of abrasive blasting hoods. Employees used supplied air blasting hoods during abrasive blasting activities.
Recent events (2)
- · I (S) $4773
- · Z (S) $7956
1910.134 E01
- Issued
- May 1, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $7,956 · Current $4,773 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) At the facility, where employees had not received medical evaluations prior to the use of elastomeric half-face respirators. Employees used the half-face respirators during powder coating activities. b) At the facility, where an employee had not received a medical evaluation prior to the use of an abrasive blasting hood. The employee used the blasting hood during abrasive blasting activities.
Recent events (2)
- · I (S) $4773
- · Z (S) $7956
1910.134 F02
- Issued
- May 1, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $7,956 · Current $4,773 Reduced
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) At the facility, where employees had not received fit testing prior to the use of elastomeric half-face respirators. Employees used 3M half-face respirators during powder coating activities.
Recent events (2)
- · I (S) $4773
- · Z (S) $7956
1910.307 B
- Issued
- May 1, 2019
- Abate by
- Jun 5, 2019
- Penalty
- Initial $9,282 · Current $5,569 Reduced
General-duty citation text
29 CFR 1910.307(b): Areas designated as hazardous (classified) locations under the Class and Zone system and areas designated under the Class and Division system established after August 13, 2007 were not properly documented: a) At the facility near the powder coating booth, where hazardous (classified) locations, such as, but not limited to, areas subject to deposits of combustible residue and areas in close proximity to powder coating operations were not documented.
Recent events (2)
- · I (S) $5569
- · Z (S) $9282
1910.307 C
- Issued
- May 1, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: a) At the facility near the powder coating booth, where the fluorescent lighting above the spray booth was not approved for the location. Employees spray a flammable powder coating. This condition exposed employees to an explosion/fire hazard. b) At the facility inside the powder coating booth, where the fluorescent lighting inside the spray booth was not approved for the location. Employees spray a flammable powder coating. This condition exposed employees to an explosion/fire hazard.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Serampore Industries
View Serampore Industries's full OSHA safety record →
More inspections in this industry (NAICS 423510)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343703898.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.