SAN ANTONIO, TX —
OSHA Inspection: HEB
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HEB in 5103 RITTIMAN RD, SAN ANTONIO, TX 78204 (NAICS 424410). OSHA activity number 343705182.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEB
- Site address
- 5103 RITTIMAN RD
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78204
- Mailing
- 9120 RITTIMAN ROAD, SAN ANTONIO, TX 78204
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424410
- Employees
- 2000
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.119 E05
- Issued
- Apr 8, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $13,260 · Current $7,956 Reduced
General-duty citation text
29 CFR 1910.119(e)(5): The employer did not promptly evaluate the PHA team's recommendation to evaluate the locations and operations of the facility HVAC equipment and taking measures to prevent the infiltration of ammonia into the facility. This violation was most recently observed on or about January 9, 2019, in the Combo Warehouse Ammonia Refrigeration Unit, when the employer failed to promptly address the hazard of ammonia infiltration into the facility through the HVAC equipment during ammonia release.
Recent events (2)
- — I (S) $7956
- — Z (S) $13260
1910.119 D03 I B
- Issued
- Apr 8, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(d)(3)(i)(B): Piping and instrument diagrams (P&ID's) were not up to date and inaccurate; a) This violation was most recently observed on or about January 9, 2019, in the Combo Warehouse Ammonia Refrigeration Unit, when the employer failed to document the sight glass lower piping connection to the High Pressure Receiver (P&ID06). b) This violation was most recently observed on or about January 9, 2019, in the Combo Warehouse Ammonia Refrigeration Unit, when the employer failed to document the correct pressure rating information on Oil Pot-1 (P&ID04).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.119 F03
- Issued
- Apr 8, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.119(f)(3): Operating Procedures were not reviewed as often as necessary and certified annually to assure that they reflect current operating practice and accurate. This violation was most recently observed on or about January 9, 2019, in the Combo Warehouse Ammonia Refrigeration Unit, when the employer failed to review as often as necessary and update the Drain Circulator Oil Pot procedure to incorporate new valve location (V108) when the quick action valve was installed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at HEB
View HEB's full OSHA safety record →
More inspections in this industry (NAICS 424410)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343705182.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.