Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DIFRUSCIA INDUSTRIES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of DIFRUSCIA INDUSTRIES, INC. in 1425 CRANSTON STREET, CRANSTON, RI 02920 (NAICS 332813). OSHA activity number 343705869.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Difruscia Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Difruscia Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1425 CRANSTON STREET
City
CRANSTON
State
RI
ZIP
02920
Mailing
1425 CRANSTON STREET, CRANSTON, RI 02920
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
47
Ownership type
A

9 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 18, 2019
Penalty
Initial $7,956 · Current $3,978 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:    (a) Spray painting:  On or about 4/4/19 the employer did not ensure that an employee performing cleaning and maintenance activities on the top of a spray booth was protected from a fall of approximately 8 feet to the floor.
Recent events (2)
  • — I (S) $3978
  • — Z (S) $7956

1910.106 B06

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 18, 2019
Penalty
Initial $5,304 · Current $2,652 Reduced
29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition.  Sources of ignition may include open flames, lightning, smoking, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat:     (a) Solvent spray paint storage area:  On or about 1/10/19 the employer did not take precautions to prevent ignition of flammable vapors by eliminating or controlling sources of static electricity by bonding the waste solvent storage container to ground.
Recent events (2)
  • — I (S) $2652
  • — Z (S) $5304

1910.107 B05 I

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 18, 2019
Abate by
Aug 2, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(i): The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute:  (a) Spray booth #1:  On or about 1/10/19 the average air speed over the open face of the paint spray booth was less than 100 linear feet per minute.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B05 I

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained:  (a) Spray booth #1:  On or about 1/10/19 the manometer used to indicate the air speed was not functioning.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 B05 IV

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 18, 2019
Abate by
Aug 2, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:  (a) Solvent Spray booth #1:  On or about 1/10/19 the spray booth, on the downstream and upstream sides of filters, was not protected with approved automatic sprinklers.  (a) Powder Coat booth #1:  On or about 1/10/19 the spray booth, on the downstream and upstream sides of filters, was not protected with approved automatic sprinklers.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.133 A01

Other-than-serious 1 instance 8 exposed
Issued
Jun 18, 2019
Penalty
Initial $5,304 · Current $0 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:       (a) Solvent spray booths:  On or about 1/10/19 protective eye equipment was not required when preparing and spraying Cerakote E-160 where there was a reasonable probability of injury that could be prevented by such equipment.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5304

1910.134 C01

Other-than-serious 1 instance 8 exposed
Issued
Jun 18, 2019
Abate by
Aug 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a) Powder and Solvent Spray Operations:  On or about 1/10/19 a written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix), with worksite specific procedures, was not established and implemented for required respirator use.    ABATEMENT NOTE: In accordance with 29 CFR 1910.134(c)(1)(i) thru 1910.134(c)(1)(ix)the respirator program must be site specific and include the following:      a. Procedures for selecting respirators for use in the workplace, including an evaluation of respiratory hazards in the workplace and a reasonable estimate of employee exposure.  (Note: The Rhode Island OSHA Consultation Program (phone: 401-222-7745) provides free monitoring services for qualifying employers);  b. Medical evaluations of employees required to use respirators to determine the employee's ability to use a respirator;  c. Fit testing procedures for tight-fitting respirators. (Note: this service may be available from your respirator vendor);   d. Procedures for proper use of respirators in routine and reasonable foreseeable emergency situations;   e. Procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding and otherwise maintaining respirators;  f. Training of employees in the respiratory hazards to which they are potentially exposed during routine and emergency situations;  g. Training of employees in the proper use of respirators, including putting on and removing them, any limitations on their use, and their maintenance; and  h. Procedures for regularly evaluating the effectiveness of the program.  Further assistance in developing respirator programs is available in OSHA Small Entity Compliance Guide for the Revised Respiratory Protection Standard.  This document is available on the internet at the following website address:    http://www.osha.gov/Publications/3384small-entity-for-respiratory-protection-standard-rev.pdf
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 D01 III

Other-than-serious 1 instance 8 exposed
Issued
Jun 18, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  (a) Spray coating areas:  On or about 1/10/19 the employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K

Other-than-serious 1 instance 8 exposed
Issued
Jun 18, 2019
Abate by
Aug 30, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k): The employer did not provided effective training to employees who are required to use respirators:    (a) Solvent and powder coating operations:  On or about 1/10/19 the employer did not provide effective training to employees who are required to use respirators.