CINCINNATI, OH —
OSHA Inspection: AMERICAN SCAFFOLDING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AMERICAN SCAFFOLDING, INC. in 1071 CELESTIAL ST., CINCINNATI, OH 45202 (NAICS 238990). OSHA activity number 343709838.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN SCAFFOLDING, INC.
- Site address
- 1071 CELESTIAL ST.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45202
- Mailing
- 7161 EAGLE CREEK RD, CINCINNATI, OH 45247
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 70
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 A01
- Issued
- Jun 7, 2019
- Abate by
- Jul 3, 2019
- Penalty
- Initial $8,354 · Current $5,000 Reduced
General-duty citation text
29 CFR 1926.451(a)(1): Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. a)On or about December 26, 2018 to January 8, 2019 employees and or employees of other on-site subcontractors worked from a partially enclosed wind screened scaffolding system of which each scaffold wall anchor tie lag shield component device and component wall anchor tie lag shields/lags devices into brick mortar was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended non-perpendicular uplift wind force pressure loads applied or transmitted in association with the partially enclosed wind screened scaffolding systems geographic conditions, terrain, proximity of other adjacent structures, shape of adjacent structures, reinforced plastic enclosure material and wind clips exposing the employees and or employees of other on site subcontractors to the hazards associated with scaffold collapse and falls in excess of 20 feet.
Recent events (2)
- — I (S) $5000
- — Z (S) $8354
1926.451 F12
- Issued
- Jun 7, 2019
- Abate by
- Jul 3, 2019
- Penalty
- Initial $8,354 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(12): Wind screens shall not be used unless the scaffold is secured against the anticipated wind forces imposed. a) On or about December 26, 2018 to January 9, 2019 employees and or employees of other on site subcontractors worked from a partially enclosed wind screened scaffolding system which was not initially designed or constructed of nor anchored to materials which could secure the scaffold to withstand against without failure anticipated non-perpendicular uplift transmitted wind force pressure loads imposed exposing the employees and or employees of other on site subcontractors to the hazards associated with scaffold collapse and falls in excess of 20 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $8354
1926.451 A06
- Issued
- Jun 7, 2019
- Abate by
- Jul 3, 2019
- Penalty
- Initial $8,354 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. a) On or about December 26, 2018 to January 8, 2019 employees and or employees of other on- site subcontractors worked from a partially enclosed wind screened scaffolding system which was not initially designed by a qualified person and was not constructed of nor anchored to materials such as each utilized scaffold wall anchor tie lag shield component device and component wall tie lag shields/lags devices utilized anchored into brick mortar to withstand without failure transmitted non-perpendicular uplift wind force pressure loads in accordance with a qualified persons scaffold design parameters associated to be inclusive with a partially enclosed wind screened scaffolding systems geographic conditions, terrain, proximity of other adjacent structures, shape of adjacent structures, reinforced plastic enclosure material and wind clips exposing the employees and or employees of other on site subcontractors to the hazards associated with scaffold collapse and falls in excess of 20 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $8354
More inspections at American Scaffolding, INC.
View American Scaffolding, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343709838.