Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN SCAFFOLDING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN SCAFFOLDING, INC. in 1071 CELESTIAL ST., CINCINNATI, OH 45202 (NAICS 238990). OSHA activity number 343709838.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Scaffolding, INC. — free Get an email when a new federal OSHA severe-injury report for American Scaffolding, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1071 CELESTIAL ST.
City
CINCINNATI
State
OH
ZIP
45202
Mailing
7161 EAGLE CREEK RD, CINCINNATI, OH 45247
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
70
Ownership type
A

3 citations on file for this inspection.

1926.451 A01

Serious Gravity 10 2 instances 10 exposed
Issued
Jun 7, 2019
Abate by
Jul 3, 2019
Penalty
Initial $8,354 · Current $5,000 Reduced
29 CFR 1926.451(a)(1): Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.     a)On or about December 26, 2018 to January 8, 2019 employees and or employees of other      on-site subcontractors worked from a partially enclosed wind screened scaffolding system of which each scaffold wall anchor tie lag shield component device and component wall anchor tie lag shields/lags devices into brick mortar was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended non-perpendicular uplift wind force pressure loads applied or transmitted in association with the partially enclosed wind screened scaffolding systems geographic conditions, terrain, proximity of other adjacent structures, shape of adjacent structures, reinforced plastic enclosure material and wind clips exposing the employees and or employees of other on site subcontractors to the hazards associated with scaffold collapse and falls in excess of 20 feet.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $8354

1926.451 F12

Serious Gravity 10 2 instances 10 exposed
Issued
Jun 7, 2019
Abate by
Jul 3, 2019
Penalty
Initial $8,354 · Current $0 Reduced
29 CFR 1926.451(f)(12): Wind screens shall not be used unless the scaffold is secured against the anticipated wind forces imposed.     a) On or about December 26, 2018 to January 9, 2019 employees and or employees of other on site subcontractors worked from a partially enclosed wind screened scaffolding system which was not initially designed or constructed of nor anchored to materials which could secure the scaffold to withstand against without failure anticipated non-perpendicular uplift transmitted wind force pressure loads imposed exposing the employees and or employees of other on site subcontractors to the hazards associated with scaffold collapse and falls in excess of 20 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8354

1926.451 A06

Deleted Serious Gravity 10 2 instances 10 exposed
Issued
Jun 7, 2019
Abate by
Jul 3, 2019
Penalty
Initial $8,354 · Current $0 Reduced
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design.   a) On or about December 26, 2018 to January 8, 2019 employees and or employees of other      on- site subcontractors worked from a partially enclosed wind screened scaffolding system which was not initially designed by a qualified person and was not constructed of nor anchored to materials such as each utilized scaffold wall anchor tie lag shield component device and component wall tie lag shields/lags devices utilized anchored into brick mortar to withstand without failure transmitted non-perpendicular uplift wind force pressure loads in accordance with a qualified persons scaffold design parameters associated to be inclusive with a partially enclosed wind screened scaffolding systems geographic conditions, terrain, proximity of other adjacent structures, shape of adjacent structures, reinforced plastic enclosure material and wind clips exposing the employees and or employees of other on site subcontractors to the hazards associated with scaffold collapse and falls in excess of 20 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8354

View American Scaffolding, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343709838.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.