Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLUMBUS CAR CLEANING COMPANY, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of COLUMBUS CAR CLEANING COMPANY, INC. in 4881 SINCLAIR ROAD, COLUMBUS, OH 43229 (NAICS 811192). OSHA activity number 343712253.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Columbus CAR Cleaning Company, INC. — free Get an email when a new federal OSHA severe-injury report for Columbus CAR Cleaning Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4881 SINCLAIR ROAD
City
COLUMBUS
State
OH
ZIP
43229
Mailing
34522 N. SCOTTSDALE ROAD UNIT 102-420, SCOTTSDALE, AZ 85266
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811192
Employees
15
Ownership type
A

7 citations on file for this inspection.

1910.23 C02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 25, 2019
Abate by
Mar 7, 2019
Penalty
Initial $3,031 · Current $0 Reduced
29 CFR 1910.23(c)(2): Each stepladder or combination ladder used in a stepladder mode is equipped with a metal spreader or locking device that securely holds the front and back sections in an open position while the ladder is in use;  a. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, where an employee used a step ladder to gain access to the top of the miter machine, the ladder was leaned against the miter machine and in the closed position, thereby exposing employees to fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3031

1910.147 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 25, 2019
Abate by
May 11, 2019
Penalty
Initial $5,304 · Current $3,600 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, the employer failed to establish an energy control program to include specific procedures, employee training, and periodic inspections, resulting in the unexpected startup of the miter machine causing the victim to be caught in the miter machine.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $5304

1910.219 D01

Serious Gravity 10 2 instances 13 exposed
Issued
Feb 25, 2019
Abate by
Apr 11, 2019
Penalty
Initial $5,304 · Current $3,600 Reduced
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.  a. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, where employees accessed the control room, there were unguarded pulleys on the high pressure pump for the prep gun, thereby exposing employees to a caught-in hazard.  b. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, where employees accessed the control room, there were unguarded pulleys on the high pressure pump for the Omni Wash, thereby exposing employees to a caught-in hazard.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $5304

1910.219 E01 I

Serious Gravity 10 1 instance 13 exposed
Issued
Feb 25, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section.  a. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, where employees accessed the control room, there were unguarded belts on the high pressure pump for the prep gun, thereby exposing employees to a caught-in hazard.  b. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, where employees accessed the control room, there were unguarded belts on the high pressure pump for the Omni Wash, thereby exposing employees to a caught-in hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 10 1 instance 13 exposed
Issued
Feb 25, 2019
Abate by
Apr 11, 2019
Penalty
Initial $5,304 · Current $3,600 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings shall be effectively closed to afford protection substantially equivalent to the wall of the equipment.  a. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, where employees accessed the control room, there were unused openings in the side of the electrical box on the west side of the room, thereby exposing employees to an electrical contact hazard.  b. a. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, where employees accessed the control room, there were unused openings in the circuit breaker panel located on the east side of the room, thereby exposing employees to an electrical contact hazard.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $5304

1910.305 B02 I

Serious Gravity 5 1 instance 13 exposed
Issued
Feb 25, 2019
Abate by
Apr 11, 2019
Penalty
Initial $3,789 · Current $2,557 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.   a. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, where employees accessed the control room, the electrical cover for the Omni Wash junction box was missing, thereby exposing employees to an electrical contact hazard.
Recent events (2)
  • — I (S) $2557
  • — Z (S) $3789

1910.305 G02 III

Serious Gravity 5 1 instance 13 exposed
Issued
Feb 25, 2019
Abate by
Apr 11, 2019
Penalty
Initial $3,789 · Current $2,556 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.   a. Located at 4881 Sinclair Road, Columbus, Ohio, 43229: On or about January 14, 2019, where employees accessed the control room, the electrical cable clamp was not secured to the Omni Wash junction box permitting a pull to be directly transmitted to the joints in the box, thereby exposing employees to an electrical contact hazard.
Recent events (2)
  • — I (S) $2555.82
  • — Z (S) $3789

View Columbus CAR Cleaning Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343712253.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.