SOUTH ELGIN, IL ·
OSHA Inspection: AWT LABELS & PACKAGING
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AWT LABELS & PACKAGING in 393 JOSEPH DR, SOUTH ELGIN, IL 60177 (NAICS 323111). OSHA activity number 343716817.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AWT LABELS & PACKAGING
- Site address
- 393 JOSEPH DR
- City
- SOUTH ELGIN
- State
- IL
- ZIP
- 60177
- Mailing
- 393 JOSEPH DR, SOUTH ELGIN, IL 60177
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 40
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Feb 6, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $5,115 · Current $3,333 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): South Elgin, Illinois plant, slitting, KYMC slitter no. 1 (model no. SMART-1300, serial no. 4281), on or about January 8, 2019, slitter operators engaged in cleaning and setup tasks on energized equipment were not provided with adequately developed and documented machine-specific hazardous energy control (lockout tagout) procedures. The procedures lacked specific steps to isolate and control hazardous energy sources, steps for the placement of lockout devices, and specific verifications steps to determine the effectiveness of the energy control measures. Operators had their hands exposed to caught-in hazards from contact with rollers' in-going nip points. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- · I (S) $3333
- · Z (S) $5115
1910.147 C07 I
- Issued
- Feb 6, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: South Elgin, Illinois plant, slitting, KYMC slitter no. 1 (model no. SMART-1300, serial no. 4281), on or about January 8, 2019, slitter operators assigned to clean and setup equipment that required the use of lockout/tagout were not adequately trained on safe application, usage, methods, and means to isolate and control hazardous energy sources. Operators had their hands exposed to caught-in hazards from contact with rollers' in-going nip points. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.147 C06 I
- Issued
- Feb 6, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $5,115 · Current $3,333 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: South Elgin, Illinois plant, slitting, KYMC slitter no. 1 (model no. SMART-1300, serial no. 4281) - on or about January 8, 2019, the employer did not conduct inspections of their hazardous energy control procedures at least annually to identify and correct any deviations or procedural inadequacies. Slitter operators assigned to perform cleaning and setup activities had their hands exposed to caught-in hazards from contact with rollers' in-going nip points. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
- · I (S) $3333
- · Z (S) $5115
1910.147 D
- Issued
- Feb 6, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $5,115 · Current $3,334 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedure) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): (1) prepare for shut down by recognizing energy hazards and its controls, (2) turn off and shut down the machines, (3) physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) affix lockout or tagout devices to each energy isolating device, (5) render safe all potentially hazardous stored or residual energy, (6) verify that isolation and de-energization of the machine or equipment have been accomplished. South Elgin, Illinois plant, slitting, KYMC slitter no. 1 (model no. SMART-1300, serial no. 4281), on or about January 8, 2019, slitter operators engaged in roller cleaning tasks were not required to follow the established sequence for hazardous energy isolation (Lockout Tagout) of equipment, and relied on a stopped automation cycle to prevent unexpected startup. Operators had their hands exposed to caught-in hazards from contact with rollers' in-going nip points. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).