HOLTS SUMMIT, MO —
OSHA Inspection: DOOLITTLE TRAILER MANUFACTURING COMPANY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DOOLITTLE TRAILER MANUFACTURING COMPANY in 2455 DOOLITTLE DRIVE, HOLTS SUMMIT, MO 65043 (NAICS 336212). OSHA activity number 343716957.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DOOLITTLE TRAILER MANUFACTURING COMPANY
- Site address
- 2455 DOOLITTLE DRIVE
- City
- HOLTS SUMMIT
- State
- MO
- ZIP
- 65043
- Mailing
- 2455 DOOLITTLE DRIVE, HOLTS SUMMIT, MO 65043
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336212
- Employees
- 167
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.106 E06 I
- Issued
- Mar 26, 2019
- Abate by
- Apr 19, 2019
- Penalty
- Initial $5,796 · Current $4,057 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: In the paint department mix room, when transfer from 55 gal drums of flammables, such as paint, primer, catalyst, and MEK, was made, the drums were not grounded. (Note: grounding rods were present but none of the approximate nine drums present were grounded, even those being drawn from at the time of the inspection.) Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $4057.2
- — Z (S) $5796
1910.107 C09 I
- Issued
- Mar 26, 2019
- Abate by
- Apr 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(9)(i): 29 CFR 1910.107(c)(9)(i): All metal parts of piping systems conveying flammable or combustible liquids were not properly electrically grounded in an effective and permanent manner: In the paint department mix room, when transfer from 55 gal drums of flammables, such as paint, primer, catalyst, and MEK, was made, the drums were not grounded. (Note: grounding rods were present but none of the approximate nine drums present were grounded, even those being drawn from at the time of the inspection.) Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G02
- Issued
- Mar 26, 2019
- Abate by
- Apr 19, 2019
- Penalty
- Initial $4,347 · Current $3,043 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: a. At the time of the inspection, plastic sheeting, used to cover the walls of the spray booth, had not been changed for at least over a week, and was said to have been changed approximately monthly, was covered with overspray, from the spraying of flammables such as solvent based primer and paint. b. At the time of the inspection, overspray residue covered the paint booth floor at least to a depth of approximately 1/16", and had not been changed for at least a month. c. Spray guns were flushed of remaining solvent based, flammable paint, by spraying the contents onto the floor of the spray booth resulting in standing flammable liquid on the floor, adding to the potential fire load in the booth. The liquid was not cleaned daily. (Note: any remaining paint should be deposited in a container designed for the purpose.) Abatement documentation is required for this violation.
Recent events (2)
- — I (S) $3042.9
- — Z (S) $4347
More inspections at Doolittle Trailer Manufacturing Company
View Doolittle Trailer Manufacturing Company's full OSHA safety record →
More inspections in this industry (NAICS 336212)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343716957.