Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: DAYON MANUFACTURING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DAYON MANUFACTURING, INC. in 1820 NEW BRITAIN AVENUE, FARMINGTON, CT 06032 (NAICS 332612). OSHA activity number 343717005.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dayon Manufacturing, INC. for free Get an email when a new federal OSHA severe-injury report for Dayon Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1820 NEW BRITAIN AVENUE
City
FARMINGTON
State
CT
ZIP
06032
Mailing
P.O. BOX 588, FARMINGTON, CT 06034
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332612
Employees
20
Ownership type
Private (A)

5 citations on file for this inspection.

1910.133 A03

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 20, 2019
Penalty
Initial $2,576 · Current $1,803 Reduced
29 CFR 1910.133(a)(3): The employer did not ensure that each affected employee who wore prescription lenses while engaged in operations that involved eye hazards wore eye protection that incorporated the prescription in its design, or wore eye protection that could be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses:  A.  On or about January 17, 2019, Grinding Room:  Two employees working in the grinding area were wearing their regular prescription glasses.  The room was provided with signage requiring protective eyewear.
Recent events (2)
  • · I (S) $1803.2
  • · Z (S) $2576

1910.178 L04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 20, 2019
Abate by
May 6, 2019
Penalty
Initial $2,576 · Current $1,803 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  A.  On or about January 17, 2019, Facility:  Three employees were allowed to operate the company's propane powered forklift.  Training had not been documented since 2014.
Recent events (2)
  • · I (S) $1803.2
  • · Z (S) $2576

1910.219 D01

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 20, 2019
Abate by
May 6, 2019
Penalty
Initial $2,576 · Current $1,803 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):   A.  On or about January 17, 2019, Torsion Department:  Power transmission belt and pulley assemblies on two Sleeper + Hartley spring machines, #1 and #3, were not provided with enclosure guards.  The belt and pulley assemblies were located at the base of the equipment where employees could be caught in the nip points created as the belt went around the pulley.
Recent events (2)
  • · I (S) $1803.2
  • · Z (S) $2576

1910.219 F01

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 20, 2019
Abate by
May 6, 2019
Penalty
Initial $2,576 · Current $1,803 Reduced
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii):    A.  On or about January 17, 2019, Torsion Department:  In the following instances, gears were not enclosed by complete enclosure guards to prevent access to the point of operation:  1.  Sleeper + Hartley #1 2.  Sleeper + Hartley #3
Recent events (2)
  • · I (S) $1803.2
  • · Z (S) $2576

1910.303 G01 III

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 20, 2019
Penalty
Initial $2,190 · Current $1,533 Reduced
29 CFR 1910.303(g)(1)(iii): The employer did not ensure that at least one entrance of sufficient area was provided to give access to the working space about electric equipment 600 Volts, nominal, or less:  A.  On or about January 17, 2019, Heat Treat:  Access to the Square D 120/240 V Load Center panel behind the Branson Vapor Degreaser was blocked by the placement of a work table containing racks.  The panel provided power to exhaust and pedestal fans, lights in heat treat and grinding areas, the 900-degree oven, chiller, degreaser and still.
Recent events (2)
  • · I (S) $1533
  • · Z (S) $2190