Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: MAC MEDICAL, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MAC MEDICAL, INC. in 820 S MULLBERRY ST, MILLSTADT, IL 62260 (NAICS 339113). OSHA activity number 343719464.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MAC Medical, INC. for free Get an email when a new federal OSHA severe-injury report for MAC Medical, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MAC MEDICAL, INC.
Site address
820 S MULLBERRY ST
City
MILLSTADT
State
IL
ZIP
62260
Mailing
820 S MULLBERRY ST, MILLSTADT, IL 62260
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339113
Employees
107
Ownership type
Private (A)

1 citation on file for this inspection.

1910.147 F01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 4, 2019
Abate by
Mar 28, 2019
Penalty
Initial $11,934 · Current $7,160 Reduced
29 CFR 1910.147(f)(1): Testing or positioning of machines, equipment or components thereof.  In situations in which lockout or tagout devices must be temporarily removed from the energy isolating devices and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of action was not followed:     Employees who performed testing or positioning of the Timesavers 4200 Sanding Machine were not required to follow the required sequence of actions during belt adjustment and were exposed to caught-in hazards from the rotating belt.   (1) Clear the machine or equipment of tools and materials in accordance with paragraph (e)(1) of this section,  (2) Remove employees from the machine or equipment area in accordance with paragraph (e)(2) of this section,  (3) Remove the lockout or tagout device as specified in paragraph (e)(3) of this section,  (4) Energize and proceed with testing or positioning,  (5) Deenergize all systems and reapply energy control measures in accordance with paragraph (d) of this section to continue the servicing and maintenance.
Recent events (2)
  • · I (S) $7160
  • · Z (S) $11934

View MAC Medical, INC.'s full OSHA safety record →