MILLSTADT, IL ·
OSHA Inspection: MAC MEDICAL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAC MEDICAL, INC. in 820 S MULLBERRY ST, MILLSTADT, IL 62260 (NAICS 339113). OSHA activity number 343719464.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAC MEDICAL, INC.
- Site address
- 820 S MULLBERRY ST
- City
- MILLSTADT
- State
- IL
- ZIP
- 62260
- Mailing
- 820 S MULLBERRY ST, MILLSTADT, IL 62260
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339113
- Employees
- 107
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1910.147 F01
- Issued
- Mar 4, 2019
- Abate by
- Mar 28, 2019
- Penalty
- Initial $11,934 · Current $7,160 Reduced
General-duty citation text
29 CFR 1910.147(f)(1): Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating devices and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of action was not followed: Employees who performed testing or positioning of the Timesavers 4200 Sanding Machine were not required to follow the required sequence of actions during belt adjustment and were exposed to caught-in hazards from the rotating belt. (1) Clear the machine or equipment of tools and materials in accordance with paragraph (e)(1) of this section, (2) Remove employees from the machine or equipment area in accordance with paragraph (e)(2) of this section, (3) Remove the lockout or tagout device as specified in paragraph (e)(3) of this section, (4) Energize and proceed with testing or positioning, (5) Deenergize all systems and reapply energy control measures in accordance with paragraph (d) of this section to continue the servicing and maintenance.
Recent events (2)
- · I (S) $7160
- · Z (S) $11934
More inspections at MAC Medical, INC.
View MAC Medical, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 339113)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343719464.