FORT BELVOIR, VA ·
OSHA Inspection: GRAM JV
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GRAM JV in BUILDING 247 MISSLE DEFENSE AGENCY, FORT BELVOIR, VA 22060 (NAICS 236220). OSHA activity number 343720462.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GRAM JV
- Site address
- BUILDING 247 MISSLE DEFENSE AGENCY
- City
- FORT BELVOIR
- State
- VA
- ZIP
- 22060
- Mailing
- 101 DAVIS AVE SW, LEESBURG, VA 20175
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 220
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.34 B
- Issued
- Mar 19, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $4,347 · Current $4,347
General-duty citation text
29 CFR 1926.34(b): "Exit marking." Exits shall be marked by a readily visible sign. Access to exits shall be marked by readily visible signs in all cases where the exit or way to reach it is not immediately visible to the occupants. a) Building 247, third floor: On or about 01/16/2019, exit and exit access signs were not posted on the third floor. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (O) $4347
- · Z (S) $4347
1926.150 C01 IV
- Issued
- Mar 19, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(c)(1)(iv): There was not at least one fire extinguisher located adjacent to stairways on each floor of a multistory building: a) Building 247 third floor: On or about 01/16/2019, a fire extinguisher was not provided adjacent to each of the (4) four stairways of the multistory building. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.403 I02 I
- Issued
- Mar 19, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $5,796 · Current $0 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph. a) Building 247, Section 1D: On or about 01/16/2019, the cover plate to a 120-volts mounted light switch was pulled away from its enclosure as a result exposed subcontractor employees to live conductors. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- · I (S) $0
- · Z (S) $5796
1926.501 B01
- Issued
- Mar 19, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $7,246 · Current $7,246
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Building 247, Roof: On or about 01/16/2019, employees and subcontractors were not provided with fall protection while on the roof with an unguarded parapet as a result employees were exposed to an approximate 30 and 40 feet fall hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.