Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: ROB ROBERTS CUSTOM GUN WORKS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ROB ROBERTS CUSTOM GUN WORKS, INC. in 775 KYLER ROAD, BATESVILLE, AR 72501 (NAICS 811490). OSHA activity number 343721262.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ROB Roberts Custom GUN Works, INC. for free Get an email when a new federal OSHA severe-injury report for ROB Roberts Custom GUN Works, INC. is published. One employer, no account, unsubscribe in one click.
Site address
775 KYLER ROAD
City
BATESVILLE
State
AR
ZIP
72501
Mailing
775 KYLER ROAD, BATESVILLE, AR 72501
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811490
Employees
18
Ownership type
A

5 citations on file for this inspection.

1910.106 E06 I

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 19, 2019
Abate by
May 10, 2019
Penalty
Initial $5,304 · Current $3,182 Reduced
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:  (a) On or about January 16, 2019, and at times prior thereto, in the shop, the employer failed to ensure that precautions were taken to prevent lacquer thinner from being transported or dispensed within close proximity to the 5-ft. x 5-ft. x 8-ft. tall electric heat-treat oven.
Recent events (2)
  • · I (S) $3182.4
  • · Z (S) $5304

1910.106 E06 II

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 19, 2019
Abate by
May 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected.  On or about January 16, 2019, and at times prior thereto, the employer failed to ensure the Axalta lacquer thinner 3-gallon metal bucket and vat tank were grounded /bonded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 E01

Serious Gravity 5 1 instance 18 exposed
Issued
Apr 19, 2019
Abate by
May 10, 2019
Penalty
Initial $3,789 · Current $2,273 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) On January 16, 2019, and at times prior thereto, where each employee was exposed to hazardous chemicals and the employer had not developed and implemented a written Hazard Communication program.
Recent events (2)
  • · I (S) $2273.4
  • · Z (S) $3789

1910.1200 H02 II

Serious Gravity 5 1 instance 18 exposed
Issued
Apr 19, 2019
Abate by
May 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(2)(ii): The employer did not provide information to the employees on operations in their work area where hazardous chemicals were present:  (a) On or about January 16, 2019, and at times prior thereto, at the facility, where employees used lacquer thinner, Cerakote, acetone, oil lubricant, etc. without hazard communication training.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 C01

Other-than-serious 1 instance 1 exposed
Issued
Apr 19, 2019
Abate by
May 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:   (a) On or about January 16, 2019, and at times prior thereto, where the employer required employees to wear NIOSH 3M half-face respirators with multi-gas cartridges while painting, without having conducted air quality test and developing and implementing a written Respiratory Protection program.