APPLETON, WI —
OSHA Inspection: A & P FABRICATING SOLUTIONS, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of A & P FABRICATING SOLUTIONS, LLC in 5007 WREN DRIVE, APPLETON, WI 54913 (NAICS 332312). OSHA activity number 343727889.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A & P FABRICATING SOLUTIONS, LLC
- Site address
- 5007 WREN DRIVE
- City
- APPLETON
- State
- WI
- ZIP
- 54913
- Mailing
- 5007 WREN DRIVE, APPLETON, WI 54913
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 16
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.132 D01
- Issued
- Apr 17, 2019
- Abate by
- May 24, 2019
- Penalty
- Initial $3,031 · Current $1,516 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): At a facility located at 5007 N. Wren Drive, Appleton, WI 54913; the employer did not assess the workplace to determine if hazards were present, or were likely to be present, which would necessitate the use of PPE when employees were working with open tanks of the corrosive chemical Elimitint P&P Weld Tint Remover.
Recent events (2)
- — I (S) $1515.5
- — Z (S) $3031
1910.151 C
- Issued
- Apr 17, 2019
- Abate by
- May 24, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use: At a facility located at 5007 N. Wren Drive, Appleton, WI 54913; the employer did not provide suitable facilities for quick drenching or flushing of the eyes and body when employees were working with corrosive Elimitint P&P Weld Tint Remover.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Apr 17, 2019
- Penalty
- Initial $3,789 · Current $1,895 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. At a facility located at 5007 N. Wren Drive, Appleton, WI 54914; the employer did not guard to protect operators and other employees from: a) The ingoing nip point of a HM TAS-150 Belt Grinder presented by the space between the abrasive material belt and the rear drive pulley of the machine. b) The ingoing nip point of a Kalamzaoo Vertical Belt Sander presented by the space between the abrasive material belt and the lower drive pulley of the machine.
Recent events (2)
- — I (S) $1894.5
- — Z (S) $3789
1910.305 G02 II
- Issued
- Apr 17, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $3,031 · Current $1,516 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced: At a facility located at 5007 N. Wren Drive, Appleton, WI 54913; flexible cords No. 14 or larger were repaired by splice; however, the splice did not retain the insulation and outer sheath properties, and usage characteristics of: a) A 12AWG SJTW extension cord that had its female plug replaced. b) The flexible cord insulation of the Ironton hoist's pendant above the Elimitint pickling tanks was pulled from the fitting.
Recent events (2)
- — I (S) $1515.5
- — Z (S) $3031
1910.1026 D01
- Issued
- Apr 17, 2019
- Penalty
- Initial $2,273 · Current $1,137 Reduced
0689
General-duty citation text
29 CFR 1910.1026(d)(1): Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section: At a facility located at 5007 N. Wren Drive, Appleton, WI 54913; the employer did not determin the 8-hour TWA exposure for each employee exposed to chromium (VI) while employees were welding (MIG and TIG) and plasma cutting stainless steel.
Recent events (2)
- — I (S) $1136.5
- — Z (S) $2273
1910.1026 L02 I
- Issued
- Apr 17, 2019
- Abate by
- May 24, 2019
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1026(l)(2)(i): The employer shall ensure that each employee can demonstrate knowledge of; [A] the contents of this section; and [B] the purpose and description of the medical surveillance program required by paragraph (k) of this section: At a facility located at 5007 N. Wren Drive, Appleton, WI 54913; the employer did not provide information and training to employees on the hazard of chromium (VI), the contents of this section or the purpose and description of the medical surveillance program when employees were exposed to chromium (VI) while welding (MIG and TIG) and plasma cutting stainless steel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 F06 II
- Issued
- Apr 17, 2019
- Penalty
- Initial $3,031 · Current $1,516 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: At a facility located at 5007 N. Wren Drive, Appleton, WI 54913; the employer did not ensure two tanks of Elimitint P&P Weld Tint Remover were marked, labeled or identified with the identity or hazards of the chemical in the tanks. Employees were exposed to the chemical when they placed work pieces into the tanks of Elimitint.
Recent events (2)
- — I (S) $1515.5
- — Z (S) $3031
1910.1200 G01
- Issued
- Apr 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(1): Chemical manufacturers and importers shall obtain or develop a safety data sheet for each hazardous chemical they produce or import. Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use: At a facility located at 5007 N. Wren Drive, Appleton, WI 54913; the employer did not have a safety data sheet in the workplace for Elimitint P&P Weld Tint Remover which was in open top tanks and used by employees to remove welding tint from metal work pieces.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at A & P Fabricating Solutions, LLC
View A & P Fabricating Solutions, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343727889.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.