STEELVILLE, MO ·
OSHA Inspection: ACE CASE MANUFACTURING, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ACE CASE MANUFACTURING, LLC in 490 LONG SPRINGS RD., STEELVILLE, MO 65565 (NAICS 339920). OSHA activity number 343728838.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACE CASE MANUFACTURING, LLC
- Site address
- 490 LONG SPRINGS RD.
- City
- STEELVILLE
- State
- MO
- ZIP
- 65565
- Mailing
- 160 N. MAIN ST., SAINT CLAIR, MO 63077
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339920
- Employees
- 18
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.106 E06 I
- Issued
- Feb 12, 2019
- Penalty
- Initial $3,220 · Current $2,254 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat: Containers of flammable liquids, in the glue room, were not grounded and bonded when transfer of contents was made.
Recent events (2)
- · I (S) $2254
- · Z (S) $3220
1910.106 E06 II
- Issued
- Feb 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected. Containers of flammable liquids, in the glue room, were not grounded and bonded when transfer of contents was made.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.107 C06
- Issued
- Feb 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: Spraying of flammable liquids was conducted in work space without spray booths or explosion proof equipment to prevent potential ignition of the flammable liquids being sprayed because of static electricity from non-explosion proof electrical outlets, electrical switches, and exhaust fan.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.107 C07
- Issued
- Feb 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(c)(7): Electric lamps outside of but within 20 feet of spraying area(s), and not separated therefrom by partition(s), were not protected from mechanical injury by suitable guards or by location: Spraying of flammable adhesive was conducted in work space without explosion proof equipment to prevent potential ignition of the flammable liquids being sprayed because of static electricity from non-explosion proof lighting.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.304 G05
- Issued
- Feb 12, 2019
- Penalty
- Initial $1,932 · Current $1,352 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: The glue room exhaust fan was operated without a ground pin.
Recent events (2)
- · I (S) $1352.4
- · Z (S) $1932
1910.334 A02 II
- Issued
- Feb 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: An extension cord and cutter power cord were used with the insulation damaged; inner conductors were exposed.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 339920)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343728838.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.