Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: ACE FOOD EQUIPMENT CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ACE FOOD EQUIPMENT CORP. in 71 NORTH TOWNSHIP LINE ROAD #A, LIMERICK, PA 19468 (NAICS 811310). OSHA activity number 343729844.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ACE Food Equipment Corp. for free Get an email when a new federal OSHA severe-injury report for ACE Food Equipment Corp. is published. One employer, no account, unsubscribe in one click.
Site address
71 NORTH TOWNSHIP LINE ROAD #A
City
LIMERICK
State
PA
ZIP
19468
Mailing
71 NORTH TOWNSHIP LINE ROAD #A, LIMERICK, PA 19468
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
5
Ownership type
Private (A)

7 citations on file for this inspection.

1910.107 C06

Serious Gravity 5 1 instance 1 exposed
Issued
May 8, 2019
Abate by
May 23, 2019
Penalty
Initial $2,842 · Current $1,989 Reduced

Hazardous substances 0420

29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:    a) Shop Spray Area - On or about December 28, 2018, an electrically powered fan used to remove and vent flammable aerosol vapors from a spraying area to the outside of the building was not of a type approved for Class I, Division 1 hazardous locations.
Recent events (2)
  • · I (S) $1989.4
  • · Z (S) $2842

1910.212 A05

Serious Gravity 5 1 instance 1 exposed
Issued
May 8, 2019
Abate by
May 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch:  a) Shop Spray Area - On or about December 28, 2018, the metal blades of an electrically powered fan used to remove and vent vapors from a spraying area did not have guarding to prevent employees fingers from accidental contact with rotating blades.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
May 8, 2019
Abate by
May 23, 2019
Penalty
Initial $1,705 · Current $1,194 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    a) Shop Area - On or about January 18, 2019, a Dayton brand, Model 2LKR6 bench grinder was missing the adjustable tongue guard which allowed the distance between the wheel periphery and the safety guard peripheral member to be 3/4 inch.
Recent events (2)
  • · I (S) $1193.5
  • · Z (S) $1705

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
May 8, 2019
Abate by
Jun 24, 2019
Penalty
Initial $2,273 · Current $1,591 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) Shop Area - On or about January 5, 2019, the employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified for labels, safety data sheets, and employee information and training will be met.
Recent events (2)
  • · I (S) $1591.1
  • · Z (S) $2273

1910.1200 F06

Serious Gravity 5 1 instance 1 exposed
Issued
May 8, 2019
Abate by
Jun 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section:    a) Shop Area - On or about January 5, 2019, the employer did not ensure that a container of Keystone Clean-X brand 4X4 heavy duty cleaner was labeled, tagged, or marked to provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 G08

Serious Gravity 5 1 instance 1 exposed
Issued
May 8, 2019
Abate by
Jun 24, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s)    a) Shop Area - On or about January 5, 2019, the employer did not maintain in the workplace copies of the required safety data sheets for each chemical used.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 A02 XI

Other-than-serious 1 instance 2 exposed
Issued
May 8, 2019
Abate by
May 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(xi): Cable assemblies and flexible cords and cables were not supported in place at intervals that ensure that they will be protected from physical damage:  a) Shop Spray Area - On or about January 22, 2019, temporary wiring consisting of nonmetallic-sheathed cable being used to supply power to an addition under construction was not supported to ensure that it would be protected from damage by fan blades and the metal housing of a fan motor unit.  ABATEMENT NOTE: Among other methods, one feasible and acceptable means of abatement is to follow the instructions and guidelines of ANSI/NFPA 70, "National Electrical Code" and the Underwriters Laboratory White Book information.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343729844.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.