BOISE, ID —
OSHA Inspection: PACIFIC WEST BUILDERS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PACIFIC WEST BUILDERS, INC. in 2411 E RIVERSIDE DR, BOISE, ID 83714 (NAICS 236117). OSHA activity number 343729877.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PACIFIC WEST BUILDERS, INC.
- Site address
- 2411 E RIVERSIDE DR
- City
- BOISE
- State
- ID
- ZIP
- 83714
- Mailing
- 430 E STATE ST., EAGLE, ID 83616
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236117
- Employees
- 50
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.1052 C01 II
- Issued
- Feb 28, 2019
- Abate by
- Mar 12, 2019
- Penalty
- Initial $6,630 · Current $13,261
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge (a) Building I: On or about January 15, 2019, subcontracting employees were exposed to hazards associated with lack of stairrails on stairways between the 1st and 2nd floor as well as between the 2nd and 3rd floor, respectfully. Note: Abatement certification is required.
Recent events (2)
- — I (S) $13261
- — Z (S) $6630
1926.1052 C05
- Issued
- Feb 28, 2019
- Abate by
- Mar 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(5): Handrails and the top rails of stairrail systems were not capable of withstanding, with failure, a force of at least 200 pounds (890 n) applied within 2 inches (5 cm) of the top edge, in any downward or outward direction, at every (a) Building I: On or about January 15, 2019, subcontracting employees were exposed to stairrail systems that had not been attached to the stairs properly and could not withstand 200 pounds of force applied in an outward direction. Note: Abatement certification is required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Feb 28, 2019
- Abate by
- Mar 12, 2019
- Penalty
- Initial $13,261 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Building I: On or about January 15, 2019, subcontracting employees were exposed to 20 foot fall hazards associated with a missing guardrail system along the 3rd floor walk way. Note: Abatement certification is required for this item. The Pacific West Builders, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1302125, citation number 1, item number 2 and was affirmed as a final order on June 25, 2018, with respect to a workplace located at 4909 Elisnore Ave, Meridian, ID 83642.
Recent events (2)
- — I (R) $0
- — Z (R) $13261
1926.1053 B01
- Issued
- Feb 28, 2019
- Abate by
- Mar 12, 2019
- Penalty
- Initial $3,978 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: (a) Building I: On or about January 15, 2019, subcontracting employees were accessing the roof from a portable ladder that was below the roof landing. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $3978
More inspections at Pacific West Builders, INC.
View Pacific West Builders, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236117)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343729877.