Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: RICH HARDIN CONSTRUCTION, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RICH HARDIN CONSTRUCTION, INC. in BEHIND 1600 JAMESVILLE RD ALONG RR TRACKS, SYRACUSE, NY 13214 (NAICS 238120). OSHA activity number 343730891.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rich Hardin Construction, INC. for free Get an email when a new federal OSHA severe-injury report for Rich Hardin Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
BEHIND 1600 JAMESVILLE RD ALONG RR TRACKS
City
SYRACUSE
State
NY
ZIP
13214
Mailing
150 NORRIS LANE, EATONTON, GA 31024
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
4
Ownership type
A

10 citations on file for this inspection.

1926.753 C05

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2019
Abate by
Feb 28, 2019
Penalty
Initial $2,273 · Current $1,473 Reduced
29 CFR 1926.753(c)(5): Safety latches on hooks were deactivated or made inoperable:    a)  On or about 1/18/19, At the job site:  A National 900 Series hydraulic truck crane was being utilized with a load block hook which was not equipped with a hook latch.      Abatement certification is required for this item.
Recent events (2)
  • · I (S) $1473
  • · Z (S) $2273

1926.753 D02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2019
Abate by
Feb 28, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.753(d)(2)(ii): Hooks with self closing safety latches were not used to prevent components from slipping out of the hook:  a)  On or about 1/18/19, At the job site:  Sorting hooks were being used for overhead lifting.  No hook latches were provided.   Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.753 D02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2019
Abate by
Jun 1, 2019
Penalty
Initial $2,273 · Current $1,473 Reduced
29 CFR 1926.753(d)(2)(iii): Loads were not rigged by a qualified rigger:    a)  On or about 1/18/19, At the job site:  Steel billboard parts were rigged, moved, and placed with the use of a National 900 Series hydraulic truck crane.  The rigging was not performed by a qualified rigger.      Abatement certification is required for this item.
Recent events (2)
  • · I (S) $1473
  • · Z (S) $2273

1926.761 C01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 1, 2019
Abate by
Jun 1, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.761(c)(1)(ii): Each employee performing multiple lift rigging was not provided training in the proper procedures and equipment to perform multiple lifts:    a)  On or about 1/18/19, At the job site:  Steel billboard parts were rigged, moved, and placed with the use of a National 900 Series hydraulic truck crane, including a multiple lift consisting of three horizontal members.  The rigger was not trained in proper procedures and equipment to perform a multiple lift.     Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.760 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 1, 2019
Penalty
Initial $3,978 · Current $2,581 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems:    a)  On or about 1/18/19, At the job site:  An employee erecting a billboard was not utilizing a complete fall protection system.  Employees exposed to falls of up to 38 feet.
Recent events (2)
  • · I (S) $2581
  • · Z (S) $3978

1926.761 B

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 1, 2019
Abate by
Apr 1, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.761(b): The employer did not train each employee exposed to a fall hazard in accordance with the requirements of 29 CFR 1926.761:    a)  On or about 1/18/19, At the job site:  An employee erecting a billboard was not provided with training regarding the recognition and avoidance of fall hazards along with the limitations of fall arrest systems and appropriate use of fall protection devices as is required by 29CFR 1926.761.     Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1412 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 1, 2019
Abate by
Feb 28, 2019
Penalty
Initial $2,273 · Current $1,473 Reduced
29 CFR 1926.1412(c)(1): 29 CFR 1926.1412(c)(1): Upon completion of assembly, the equipment was not inspected by a qualified person to assure that it is configured in accordance with manufacturer equipment criteria:    a)  On or about 1/18/19, At the job site:  A National 900 Series hydraulic truck crane was being operated without any inspection performed post set up.    Abatement certification is required for this item.
Recent events (2)
  • · I (S) $1473
  • · Z (S) $2273

1926.1412 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 1, 2019
Abate by
Feb 28, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1412(d)(1): A competent person must begin a visual inspection prior to each shift the equipment will be used, which must be completed before or during that shift:  a)  On or about 1/18/19, At the job site:  A National 900 Series hydraulic truck crane was being operated without any daily inspection being performed.  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1412 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 1, 2019
Abate by
Feb 28, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1412(c)(1): 29 CFR 1926.1412(c)(1): Upon completion of assembly, the equipment was not inspected by a qualified person to assure that it is configured in accordance with manufacturer equipment criteria:  a)  On or about 1/18/19, At the job site:  A National 900 Series hydraulic truck crane was being operated without any monthly inspection performed.  Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1412 F01

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 1, 2019
Abate by
Jun 1, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1412(f)(1): 29 CFR 1926.1412(f)(1): The equipment was not inspected at least every 12 months by a qualified person in accordance with paragraph (d) of this section:    a)  On or about 1/18/19, At the job site:  A National 900 Series hydraulic truck crane was being operated without any annual inspection performed.    Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343730891.