MIAMI, FL ·
OSHA Inspection: JET AVIATION SPECIALISTS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JET AVIATION SPECIALISTS, LLC in 3373 NW 107TH STREET, MIAMI, FL 33167 (NAICS 336412). OSHA activity number 343734141.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JET AVIATION SPECIALISTS, LLC
- Site address
- 3373 NW 107TH STREET
- City
- MIAMI
- State
- FL
- ZIP
- 33167
- Mailing
- 3373 NW 107 ST., MIAMI, FL 33167
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336412
- Employees
- 130
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Jul 12, 2019
- Abate by
- Sep 2, 2019
- Penalty
- Initial $13,260 · Current $9,282 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about January 15, 2019, in the combustor cell area, located at 3373 NW 107th Street, Miami, Florida 33167, the employer had not developed and documented LOTO procedures for the 42" Bullard, vertical turret lathe while the employee cleaned turnings from the turntable, exposing the employee to lacerations and broken bones.
Recent events (2)
- · I (S) $9282
- · Z (S) $13260
1910.147 C07 I
- Issued
- Jul 12, 2019
- Abate by
- Sep 2, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: On or about January 15, 2019, in the combustor cell area, located at 3373 NW 107th Street, Miami, Florida 33167, the employer had not provided training on LOTO procedures for the 42" Bullard, vertical turret lathe while the employee cleaned turnings from the turntable, exposing the employee to lacerations and broken bones.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A01
- Issued
- Jul 12, 2019
- Abate by
- Aug 7, 2019
- Penalty
- Initial $13,260 · Current $9,282 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about January 15, 2019, in the combustor cell area, located at 3373 NW 107th Street, Miami, Florida 33167, the 42" Bullard, vertical turret lathe did not have a guard around the point of operation, exposing the employee to lacerations and broken bones.
Recent events (2)
- · I (S) $9282
- · Z (S) $13260
More inspections at JET Aviation Specialists, LLC
View JET Aviation Specialists, LLC's full OSHA safety record →
More inspections in this industry (NAICS 336412)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343734141.